Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
(Optional) Enabling the Device to Detect the Current of Downstream Electrical Meters and Control Switch-on and Switch-off of Electrical Meters

(Optional) Enabling the Device to Detect the Current of Downstream Electrical Meters and Control Switch-on and Switch-off of Electrical Meters

Context

If the current of an electrical meter is too high, the electrical meter may be damaged. After the device is enabled to detect the current of downstream electrical meters and control switch-on and switch-off of electrical meters, the DCU periodically detects the current of the downstream electrical meter. If the current of a downstream electrical meter exceeds the upper threshold, the DCU switches the meter off. After the switch-off time reaches the configured interval, the DCU switches the meter on again.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run ami

    The AMI view is displayed.

  3. Run meter meter-id

    The Meter view is displayed.

  4. Run parameter current-limit enable [ evaluation-time evaluation-time ] [ reconnection-time reconnection-time ] [ current-value current-value ]

    The device is enabled to detect the current of downstream electrical meters and control switch-on and switch-off of downstream electrical meters, and the interval for detecting the current of downstream electrical meters, interval for switching a downstream electrical meter on again, and upper threshold for the current are set.