CLI-based Configuration Guide - AMI

AR500, AR510, AR531, AR550, AR1500, and AR2500 V200R010

This document describes the principles and configurations of the AMI features, and provides configuration examples of these features.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring Basic Parameters for Communication Between the Device and Front-End Processor

Configuring Basic Parameters for Communication Between the Device and Front-End Processor

Context

You can configure the basic parameters reported by the device to the front-end processor for registration.

Procedure

  1. Run the system-view command to enter the system view.
  2. Run the ami command to enter the AMI view.
  3. Run the basic heart-interval interval-value command to set the heartbeat interval.

    By default, the heartbeat interval is 5 minutes.

  4. Run the basic report-retry retry-num command to set the maximum number of retries when the device reports heartbeat packets to register with a front-end processor.

    By default, the maximum number of report retries is 3.