CLI-based Configuration Guide - IP Multicast

AR500, AR510, AR531, AR550, AR1500, and AR2500 V200R010

This document describes the concepts and configuration procedures of IP Service features on the device, and provides the configuration examples.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring the IGMP Version

Configuring the IGMP Version

Context

A multicast industrial switch router can identify IGMP messages of a version earlier than its own IGMP version but cannot identify IGMP messages of a later version. To ensure normal IGMP operation, ensure that the industrial switch router runs an IGMP version same as or later than the IGMP version of member hosts.

If there are multiple multicast industrial switch routers on a shared network segment of hosts, all host-side interfaces of these industrial switch routers must run the same IGMP version. If they are running different IGMP versions, IGMP cannot function normally on the network.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run interface interface-type interface-number

    The interface view is displayed.

  3. Run igmp version { 1 | 2 | 3 }

    The IGMP version is specified for the interface.

    By default, an interface runs IGMPv2 after IGMP is enabled on the interface.