Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0F0001FF/0F00FFFF No DIMM Is Installed (SysFWProgress)

ALM-0F0001FF/0F00FFFF No DIMM Is Installed (SysFWProgress)

Description

Alarm message:

No system memory is physically installed in the system

During BIOS startup, this alarm is generated if any of the following situation occurs: No DIMM is detected; the only DIMM is faulty; the only DIMM is installed in an correct position.

For DIMM distribution rules, see the troubleshooting manual of the related product.

This alarm is generated by the following sensor:

  • SysFWProgress

Attribute

Alarm ID

Alarm Severity

Auto Clear

iBMC: 0F0001FF

MM: 0F00FFFF

Major

Yes

Parameters

Name

Meaning

Time

Time when an alarm is generated

Sensor

Name of a sensor

Event

Details about an alarm

Severity

Severity of an alarm

Event Code

Event code that corresponds to an alarm

Impact on the System

The system fails to start because no DIMM is available.

Possible Causes

  • No DIMM is installed.
  • The only DIMM is faulty and therefore isolated by BIOS.
  • The only DIMM is installed in an incorrect position.

Procedure

  1. Power off the server and check whether DIMMs are installed.

  2. Check whether the DIMMs are installed in correct positions.

    For details about installation positions of DIMMs, see the maintenance guide for the related product.

  3. Install the required DIMMs in the correct positions. Power on the server. Check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 4.

  4. Replace the DIMMs. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 5.

  5. Contact Huawei technical support for help.