FusionServer Pro E9000 Server iBMC (Earlier than V250) Alarm Handling 02
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0142FFFF/0142FF02 Below Lower Major Threshold (SYS 1.2V)

ALM-0142FFFF/0142FF02 Below Lower Major Threshold (SYS 1.2V)

Description

Alarm message:

Below lower major threshold

This alarm is generated when the SYS 1.2 V voltage of the switch module is lower than the lower threshold for major alarms.

This alarm is generated by the following sensor:

  • SYS 1.2V

Attribute

Alarm ID

Alarm Severity

Auto Clear

iBMC: 0142FFFF

MM: 0142FF02

Major

Yes

Parameters

Name

Meaning

Time

Indicates the time when an alarm is generated.

Sensor

Name of the sensor that generated the alarm.

Event

Provides detailed information about the alarm.

Severity

Indicates the severity of the alarm.

Event Code

Indicates the event code of an alarm.

Impact on the System

The switch module power supply is abnormal and the switch module cannot power on.

Possible Causes

The switch module is faulty.

Procedure

  1. Remove and reinstall the switch module. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 2.

  2. Replace the switch module. Then check whether the alarm is cleared.

    For details about how to replace a switch module, see the related user guide.

    • If yes, no further action is required.
    • If no, go to Step 3.

  3. Contact Huawei technical support.