Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0441FFFF/0441FF17 Predictive Failure Detected (RAID Status)

ALM-0441FFFF/0441FF17 Predictive Failure Detected (RAID Status)

Description

Alarm message:

Predictive failure detected

This alarm is generated when the RAID controller card is faulty.

This alarm is generated by the following sensor:

  • RAID Status

Attribute

Alarm ID

Alarm Severity

Auto Clear

iBMC: 0441FFFF

MM: 0441FF17

Minor

Yes

Parameters

Name

Meaning

Time

Time when an alarm is generated.

Sensor

Name of the sensor that generates an alarm.

Event

Details about an alarm.

Severity

Severity of an alarm.

Event Code

Event code that corresponds to an alarm.

Impact on the System

If the RAID controller card is faulty, data in the disk cannot be accessed, which affects the system startup.

Possible Causes

  • The chip of the RAID controller card is faulty.
  • The RAID controller card supports out-of-band management, but the communication fails.
  • The RAID controller card has an uncorrectable error.
  • The number of memory ECC errors of the RAID controller card reaches the maximum.
  • The nonvolatile random access memory (NVRAM) of the RAID controller card is faulty.

Procedure

  1. Remove and install the RAID controller card. Check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to Step 2.

  2. Replace the RAID controller card. Then check whether the alarm is cleared.

    For details, see the server user guide.

    • If yes, no further action is required.
    • If no, go to Step 3.

  3. Contact Huawei technical support for help.