Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x2B02FFFF Hardware Incompatibility Major Alarm (PortN Status)

ALM-0x2B02FFFF Hardware Incompatibility Major Alarm (PortN Status)

Description

Alarm message:

Hardware incompatibility detected

The alarm is generated when a specified port hardware is incompatible.

This alarm is generated by the following sensor: PortN Status

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x2B02FFFF

Major

Yes

Parameters

Name

Meaning

N

Port number

Impact on the System

The network communication fails.

Possible Causes

  • The hardware device is incompatible.
  • The port device is damaged.
  • Replace the switch module with a new one whose working mode matches the working mode of the corresponding switch module.

Procedure

  1. Check whether the Switch Module or Switch Module controller card is replaced.

    • If yes, go to 2.
    • If no, go to 3.

  2. Check whether the replaced Switch Module controller card type is the same as the previous one..

    • If yes, go to 4.
    • If no, go to 3.

  3. Replace the controller card with a controller card that has the same type as the original one. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 4.

  4. Restart the iMana 200 or iMana 200. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 5.

  5. On the HMM WebUI, choose System Management > Information Collection, and collect logs.
  6. Contact Huawei technical support.