E9000 Server Compute Node and Switch Module iMana 200 Alarm Handling 01

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x2100FFFF Sub Compute Node Fault Major Alarm (TWIN Status)

ALM-0x2100FFFF Sub Compute Node Fault Major Alarm (TWIN Status)

Description

Alarm message:

Fault status

This alarm is generated when the system detects that the sub compute node is not in position or is faulty.

This alarm is generated by the following sensor: TWIN Status

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x2100FFFF

Major

Yes

Impact on the System

The functions of components are affected.

Possible Causes

  • The sub compute node is not installed.
  • The sub compute node is faulty.

Procedure

  1. Check whether all the sub compute nodes are installed.

    • If yes, go to 3.
    • If no, go to 2.

  2. Install all sub compute nodes. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 3.

  3. Restart the iMana 200. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If yes, go to 4.
    You can restart the iMana 200 using either of the following methods:
    • On the HMM CLI, run the telnet 0 1101 command, switch to the iMana 200 CLI, and run the ipmcset -d reset command.
    • On the HMM WebUI, choose Chassis settings > Network Settings > Node, switch to the iMana 200 WebUI, choose System > Firmware Upgrade, and click Restart iMana 200

  4. Replace the sub compute node. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If yes, go to 5.

  5. On the HMM WebUI, choose System Management > Information Collection, and collect logs.
  6. Contact Huawei technical support.