E9000 Server Compute Node and Switch Module iMana 200 Alarm Handling 01

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x0F0001FF No Memory Detected During POST (SysFWProgress)

ALM-0x0F0001FF No Memory Detected During POST (SysFWProgress)

Description

Alarm message:

No system memory is physically installed in the system

This alarm is generated during BIOS startup when any of the following occurs:

  • No DIMM is detected.
  • The only DIMM is faulty.
  • The only DIMM is installed in an incorrect position.

This alarm is generated by the following sensor: SysFWProgress

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x0F0001FF

Major

Yes

Impact on the System

The server cannot start.

Possible Causes

  • No DIMM is installed.
  • The only DIMM is faulty and therefore isolated by the BIOS.
  • The only DIMM is installed in an incorrect position.

Procedure

  1. Check the CPU and DIMM models.
  2. Use Huawei Server Compatibility Checker to check whether the CPUs and DIMMs are compatible with the server.

    • If yes, go to 4.
    • If no, go to 3.

  3. Replace the DIMMs with the ones that are compatible with the server and CPUs. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 5.

  4. Replace the DIMMs with the ones of the same model. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 5.

  5. Use the DIMMs of the same model. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 6.

  6. Replace the mainboard. Then, check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 7.

  1. On the HMM WebUI, choose System Management > Information Collection, and collect logs.
  2. Contact Huawei technical support.