Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x2700FFFF LAN Heartbeat Lost Major Alarm (Fab Heartbeat/Base Heartbeat)

ALM-0x2700FFFF LAN Heartbeat Lost Major Alarm (Fab Heartbeat/Base Heartbeat)

Description

Alarm message:

LAN heart beat lost

This alarm is generated when the sensor detects that the heartbeat of a synchronous network port between the Base planes or between Fabric planes is lost.

This alarm is generated by the following sensors:

  • Base Heartbeat
  • Fab Heartbeat

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x2700FFFF

Major

Yes

Impact on the System

The functions of components are affected.

Possible Causes

  • The switch module is not properly installed.
  • The switch module is faulty.

Procedure

  1. Reseat the switch module and then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 2.

  2. On the HMM WebUI, choose System Management > Information Collection, and collect logs.