Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-0x2100FFFF Incorrect Slot Number Major Alarm (Slot ID Status)

ALM-0x2100FFFF Incorrect Slot Number Major Alarm (Slot ID Status)

Description

Alarm message:

Fault status

This alarm is generated when the system failed to obtain the slot number or the obtained slot number is incorrect.

This alarm is generated by the sensor: Slot ID Status

Attribute

Alarm ID

Alarm Severity

Auto Clear

0x2100FFFF

Major

Yes

Impact on the System

The management system internal communication is affected, and the compute node cannot be managed effectively.

Possible Causes

  • The chassis backplane is faulty.
  • The compute node is not properly installed.
  • The compute node is faulty.

Procedure

  1. Restart the iMana 200. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If yes, go to 2.

  2. Reseat the compute node. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 3.

  3. Switch the alarmed compute mode with a norma compute node, and check whether the alarm is still generated for this compute node.

    • If yes, go to 4.
    • If no, go to 5.

  4. Replace the mainboard. Then check whether the alarm is cleared.

    • If yes, no further action is required.
    • If no, go to 5.

  5. On the HMM WebUI, choose System Management > Information Collection, and collect logs.
  6. Contact Huawei technical support.