No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Administrator Guide

HUAWEI IP Phone 7920 and 7960 V600R006C00

Describes the deployment, configuration, and maintenance of HUAWEI IP Phone 7920/7960.

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Uploading Basic IP Phone Information

Uploading Basic IP Phone Information

Prerequisites

Before connecting IP phones to the TMS, obtain the following basic information:

Files

  • DD: device description file
NOTE:
If notifypassword in the DD file is left empty, enter the default password huawei123 for this parameter, as shown in Figure 4-29.
Figure 4-29 notifyPassword
  • rule: binding rules
  • mapping: order parameter mapping rules
NOTE:

To obtain the preceding files, log in to http://support.huawei.com/enterprise/, download the software package of the corresponding IP phone model and version, and go to the dms folder obtained after the software package is decompressed.

Parameters

  • OUI: device type
  • SN: device SN
  • ModelName: IP phone model

Procedure

  1. Log in to the TMS as the root user.

    On the login page, select TR to log in to the system.

  2. Click the Subscriber/Device Inventory tab.
  3. On the Subscriber/Device Inventory tab page, under Device Type Inventory, click Add.
  4. Upload the device description file, binding rules, and order parameter mapping rules, as shown in Figure 4-30.

    NOTE:

    To ensure that DD, rule, and mapping can be successfully uploaded, use a text editing tool to open these files and change the firmwareVersion field to DEFAULT. Then change the firmwareVersion field to its original value and upload the files again.

    Figure 4-30 Uploading files
    Table 4-5 File names

    File Type

    File Name

    Descriptor

    "VALUE_DD"

    Binding Rule

    "VALUE_RULE"

    Order Parameter Mapping Rule

    "VALUE_MAPPING"

  5. Click Submit.
Translation
Download
Updated: 2019-03-06