No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

X6800 Server V100R005 User Guide 01

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Checking the Server Node

Checking the Server Node

Scenarios

Log in to the iBMC WebUI and check the health status of the Server Node. Ensure that its health status meets the environment requirements for software installation.

Data

  • IP address of the iBMC management network port on the Server Node
  • User name and password for logging in to the iBMC WebUI

Default data

Category

Name

Default Value

iBMC management network port data

IP address and subnet mask of the management network port

  • Default IP addresses of 4U4 server nodes:
    • Slot 1: 10.10.1.101
    • Slot 3: 10.10.1.103
    • Slot 5: 10.10.1.105
    • Slot 7: 10.10.1.107
    NOTE:

    N in "Node iBMC Default Network Setting 10.10.1.(100+N)" on the chassis label indicates the server node slot number, namely 1, 3, 5, and 7.

  • Default subnet mask: 255.255.255.0

iBMC login data

User name and password

  • Default user name: Administrator
  • Default password: Admin@9000

Workflow

Check the Server Node in the sequence shown in Figure 4-26. Determine the checking method based on site requirements.

Figure 4-26 Process for checking the Server Node

Procedure

  1. Check indicator status.

    Observe Server Node indicator status, and check that the device hardware is properly operating.

  2. Check the Server Node on the iBMC WebUI.

    1. Log in to the iBMC WebUI. For details, see Logging In to the iBMC WebUI or CLI of the Server Node.
    2. Choose Information on the menu bar, choose Information Summary in the navigation tree.
    3. Query Server Node version information.

      View the Server Node version information. See Figure 4-27, check that the Server Node version information meets site requirements.

    4. Query the health status of the Server Node.

      View the Server Node health status. See Figure 4-27.

      Figure 4-27 Checking the Server Node
    5. Clear alarms if any. For details, see the X6800 Server V100R005 Alarm Handling.

Translation
Download
Updated: 2018-08-28

Document ID: EDOC1100036738

Views: 9290

Downloads: 33

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next