Configuration Guide - Device Management

S9300, S9300E, and S9300X V200R012C00

This document describes the configurations of Device Management, including device status query, hardware management, CSS, SVF, PoE, OPS, OIDS, energy-saving management, information center, fault management, NTP, synchronous ethernet, PTP.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring the Alarm Function for Non-Huawei-Certified Optical Modules

Configuring the Alarm Function for Non-Huawei-Certified Optical Modules

Context

Non-Huawei-certified optical modules may not work as expected. To ensure correct functionality, you are advised to user Huawei-certified optical modules. If non-Huawei-certified optical modules are used on a device produced after July 1, 2013 (January 1, 2016 for QSFP+ 40GE optical modules, CFP 40GE optical modules and CFP 100GE optical modules), the device generates alarms that prompt you to replace these optical modules with Huawei-certified switch optical modules. In addition, older optical modules may not record vendor information, resulting in the same alarms being generated. To continue using these optical modules without generating the associated alarms, you can disable the alarm function for non-Huawei-certified optical modules.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run transceiver phony-alarm-disable

    The alarm function for non-Huawei-certified optical modules is disabled.

    By default, the alarm function for non-Huawei-certified optical modules is enabled.

    To enable the alarm function for non-Huawei-certified optical modules, run the undo transceiver phony-alarm-disable command.