Configuration Guide - Device Management

S9300, S9300E, and S9300X V200R012C00

This document describes the configurations of Device Management, including device status query, hardware management, CSS, SVF, PoE, OPS, OIDS, energy-saving management, information center, fault management, NTP, synchronous ethernet, PTP.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring OIDS Monitoring and Diagnosis

Configuring OIDS Monitoring and Diagnosis

Context

The OIDS monitoring function enables you to quickly detect faults, and the OIDS diagnosis function enables you to quickly locate and rectify faults. The OIDS monitoring function is enabled by default. After the OIDS monitoring function is enabled, the device periodically collects and saves diagnosis object attribute data to database files based on diagnosis types, diagnosis objects, and diagnosis object attributes. The OIDS module sends key performance indicator (KPI) data to service modules based on the collected diagnosis object attribute data. Service modules compare the KPI data with the defined threshold range to determine whether to generate an event. If a service module generates an event, it sends the event information to the OIDS module, which then records the information to database files.

After the OIDS diagnosis function is enabled, the switch records an OIDS event when finding that the KPI data exceeds the defined threshold, and the OIDS module determines whether to trigger OIDS diagnosis. If OIDS diagnosis is triggered, the OIDS module specifies a service module to perform diagnosis. The OIDS module records the diagnosis result received from the service module in the database.

Currently, only the CPU-CHAN diagnosis type supports the OIDS diagnosis function.

Procedure

  1. Run the system-view command to enter the system view.
  2. Run the oids monitor enable { type type-name | all } command to enable the OIDS monitoring function.

    By default, the OIDS monitoring function is enabled.

  3. Run the oids diagnose enable { type type-name | all } command to enable the OIDS diagnosis function.

    By default, the OIDS diagnosis function is disabled.

Verifying the Configuration

  • Run the display oids register-status [ type type-name ] [ slot slot-id ] command to check the status of OIDS monitoring and diagnosis functions.