S9300, S9300E, and S9300X V200R012C00

This document describes the configurations of Device Management, including device status query, hardware management, CSS, SVF, PoE, OPS, OIDS, energy-saving management, information center, fault management, NTP, synchronous ethernet, PTP.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Appendix 2: OIDS Events Supported by the Switch

Appendix 2: OIDS Events Supported by the Switch

Table 7-24  OIDS events supported by the ACL diagnosis type

Event

Type

Description

Reason

Suppression

ACL Usage High

Warning

ACL hardware entry usage is high.

ACL hardware entry usage exceeds 80%.

None

ACL Usage Normal

Recovery

ACL hardware entry usage returns to the normal range.

ACL hardware entry usage falls below 70%.

None

Table 7-25  OIDS events supported by the ARP diagnosis type

Event

Type

Description

Reason

Suppression

ARP Usage High

Warning

ARP software entry usage is high.

ARP software entry usage of LPUs exceeds 85%.

None

ARP Usage Normal

Recovery

ARP software entry usage returns to the normal range.

ARP software entry usage of LPUs falls below 75%.

None

Table 7-26  OIDS events supported by the CPU diagnosis type

Event

Type

Description

Reason

Suppression

CPU Usage High

Warning

CPU usage of boards is high.

CPU usage of boards exceeds 90%.

None

CPU Usage Normal

Recovery

CPU usage of boards returns to the normal range.

CPU usage of boards falls below 85%.

None

Table 7-27  OIDS events supported by the CPU-CHAN diagnosis type

Event

Type

Description

Reason

Suppression

CPU Port Drop Pkt

Report

Packets are dropped on the CPU port.

Packets are dropped because they exceed the rate limit of the CPU port or each queue.

None

CPU Queue Drop Pkt

Report

Packets are dropped from the CPU queue.

Packets are dropped because they exceed the rate limit of the CPU queue.

None

CPCAR Drop Pkt

Report

Packets are dropped due to CPCAR exceeding.

Packets are dropped because they exceed the CPCAR.

None

Table 7-28  OIDS events supported by the DHCPv4 diagnosis type

Event

Type

Description

Reason

Suppression

DHCPv4 Usage High

Warning

IP address usage of an IPv4 address pool is high.

IP address usage of an IPv4 address pool exceeds 85%.

None

DHCPv4 Usage Normal

Recovery

IP address usage of an IPv4 address pool returns to the normal range.

IP address usage of an IPv4 address pool falls below 85%.

None

Table 7-29  OIDS events supported by the DHCPv6 diagnosis type

Event

Type

Description

Reason

Suppression

DHCPv6 Usage High

Warning

IP address usage of an IPv6 address pool is high.

IP address usage of an IPv6 address pool exceeds 85%.

None

DHCPv6 Usage Normal

Recovery

IP address usage of an IPv6 address pool returns to the normal range.

IP address usage of an IPv6 address pool falls below 85%.

None

Table 7-30  OIDS events supported by the FIBv4 diagnosis type

Event

Type

Description

Reason

Suppression

FIBv4 Usage High

Warning

IPv4 FIB table usage is high.

IPv4 FIB table usage of LPUs exceeds 85%.

None

FIBv4 Usage Normal

Recovery

IPv4 FIB table usage returns to the normal range.

IPv4 FIB table usage of LPUs falls below 75%.

None

Table 7-31  OIDS events supported by the FIBv6 diagnosis type

Event

Type

Description

Reason

Suppression

FIBv6 Usage High

Warning

IPv6 FIB table usage is high.

IPv6 FIB table usage of LPUs exceeds 85%.

None

FIBv6 Usage Normal

Recovery

IPv6 FIB table usage returns to the normal range.

IPv6 FIB table usage of LPUs falls below 75%.

None

Table 7-32  OIDS events supported by the L3table diagnosis type

Event

Type

Description

Reason

Suppression

L3ENTRY Usage High

Warning

L3 ENTRY hardware entry usage is high.

L3 ENTRY hardware entry usage of LPUs exceeds 85%.

None

L3ENTRY Usage Normal

Recovery

L3 ENTRY hardware entry usage of LPUs returns to the normal range.

L3 ENTRY hardware entry usage of LPUs falls below 75%.

None

L3DEFIP Usage High

Warning

L3 routing hardware entry usage is high.

L3 routing hardware entry usage of LPUs exceeds 85%.

None

L3DEFIP Usage Normal

Recovery

L3 routing hardware entry usage returns to the normal range.

L3 routing hardware entry usage of LPUs falls below 75%.

None

L3INTF Usage High

Warning

L3 host hardware entry usage is high.

L3 host hardware entry usage of LPUs exceeds 85%.

None

L3INTF Usage Normal

Recovery

L3 host hardware entry usage returns to the normal range.

L3 host hardware entry usage of LPUs falls below 75%.

None

ECMP Usage High

Warning

Equal-cost routing hardware entry usage is high.

Equal-cost routing hardware entry usage of LPUs exceeds 85%.

None

ECMP Usage Normal

Recovery

Equal-cost routing hardware entry usage returns to the normal range.

Equal-cost routing hardware entry usage of LPUs falls below 75%.

None

NPFIBv4 Usage High

Warning

NP IPv4 forwarding information entry usage is high.

IPv4 forwarding information entry usage of NP boards exceeds 85%.

None

NPFIBv4 Usage Normal

Recovery

NP IPv4 forwarding information entry usage returns to the normal range.

IPv4 forwarding information entry usage of NP boards falls below 75%.

None

NPFIBv6 Usage High

Warning

NP IPv6 forwarding information entry usage is high.

IPv6 forwarding information entry usage of NP boards exceeds 85%.

None

NPFIBv6 Usage Normal

Recovery

NP IPv6 forwarding information entry usage returns to the normal range.

IPv6 forwarding information entry usage of NP boards falls below 75%.

None

Table 7-33  OIDS events supported by the MAC diagnosis type

Event

Type

Description

Reason

Suppression

MAC Usage High

Warning

MAC address entry usage is high.

MAC address entry usage of LPUs exceeds 80%.

None

MAC Usage Normal

Recovery

MAC address entry usage returns to the normal range.

MAC address entry usage of LPUs falls below 70%.

None

Table 7-34  OIDS events supported by the MCAST diagnosis type

Event

Type

Description

Reason

Suppression

IPMC Usage High

Warning

IPMC hardware entry usage is high.

IPMC hardware entry usage of LPUs exceeds 85%.

None

IPMC Usage Normal

Recovery

IPMC hardware entry usage returns to the normal range.

IPMC hardware entry usage of LPUs falls below 75%.

None

IPMC_VLAN Usage High

Warning

IPMC_VLAN hardware entry usage is high.

IPMC_VLAN hardware entry usage of LPUs exceeds 85%.

None

IPMC_VLAN Usage Normal

Recovery

IPMC_VLAN hardware entry usage returns to the normal range.

IPMC_VLAN hardware entry usage of LPUs falls below 75%.

None

Multicast Hash Conflict

Report

Hash collisions occur during multicast entry delivery.

Hash collisions occur during multicast entry delivery on LPUs.

At most one Multicast Hash Conflict event occurs on each LPU every 12 hours.

After the Multicast Hash Conflict event occurs, the Occur_Times attribute is set to Abnormal. If no hash collision occurs for three consecutive days after the Multicast Hash Conflict event occurs, the Occur_Times attribute is set to Normal.

Table 7-35  OIDS events supported by the Memory diagnosis type

Event

Type

Description

Reason

Suppression

Memory Usage High

Warning

Memory usage of boards is high.

Memory usage of boards exceeds 80%.

None

Memory Usage Normal

Recovery

Memory usage of boards returns to the normal range.

Memory usage of boards falls below 75%.

None

Table 7-36  OIDS events supported by the MPLS diagnosis type

Event

Type

Description

Reason

Suppression

VC_AND_SWAP Usage High

Warning

VC_AND_SWAP hardware entry usage is high.

VC_AND_SWAP hardware entry usage of LPUs exceeds 85%.

None

VC_AND_SWAP Usage Normal

Recovery

VC_AND_SWAP hardware entry usage returns to the normal range.

VC_AND_SWAP hardware entry usage of LPUs falls below 75%.

None

MPLS_ENTRY Usage High

Warning

MPLS_ENTRY hardware entry usage is high.

MPLS_ENTRY hardware entry usage of LPUs exceeds 85%.

None

MPLS_ENTRY Usage Normal

Recovery

MPLS_ENTRY hardware entry usage returns to the normal range.

MPLS_ENTRY hardware entry usage of LPUs falls below 75%.

None

EGR_MPLS Usage High

Warning

EGR_IP_TUNNEL_MPLS hardware entry usage is high.

EGR_IP_TUNNEL_MPLS hardware entry usage of LPUs exceeds 85%.

None

EGR_MPLS Usage Normal

Recovery

EGR_IP_TUNNEL_MPLS hardware entry usage returns to the normal range.

EGR_IP_TUNNEL_MPLS hardware entry usage of LPUs falls below 75%.

None

Table 7-37  OIDS events supported by the NAC diagnosis type

Event

Type

Description

Reason

Suppression

NAC Usage High

Warning

There are many NAC users.

The number of NAC online users exceeds 85% of the specifications.

None

NAC Usage Normal

Recovery

The number of NAC users returns to the normal range.

The number of NAC users falls below 85% of the threshold.

None

Table 7-38  OIDS events supported by the ND diagnosis type

Event

Type

Description

Reason

Suppression

ND Usage High

Warning

IPv6 neighbor software entry usage is high.

IPv6 neighbor software entry usage of LPUs exceeds 85%.

None

ND Usage Normal

Recovery

IPv6 neighbor software entry usage returns to the normal range.

IPv6 neighbor software entry usage of LPUs falls below 75%.

None

Table 7-39  OIDS events supported by the NHP diagnosis type

Event

Type

Description

Reason

Suppression

NHP Usage High

Warning

Next-hop software entry usage is high.

Next-hop software entry usage of LPUs exceeds 85%.

None

NHP Usage Normal

Recovery

Next-hop software entry usage returns to the normal range.

Next-hop software entry usage of LPUs falls below 75%.

None

Table 7-40  OIDS events supported by the Port diagnosis type

Event

Type

Description

Reason

Suppression

Bandwidth Usage Overload

Warning

Interface bandwidth usage is high.

Interface bandwidth usage exceeds 50%.

None

Bandwidth Usage Normal

Recovery

Interface bandwidth usage returns to the normal range.

Interface bandwidth usage falls below 40%.

None

CRC Packets

Report

CRC error packets are received on an interface.

The interface receives more than 10 CRC error packets.

If an interface receives more than 10 CRC error packets for the first time, an event is recorded, and the CRC_Number attribute is set to Abnormal. If the interface does not receive any CRC error packets within 12 hours, the CRC_Number attribute is restored to Normal. If the interface receives CRC error packets again within 12 hours, the system checks whether the interface receives CRC error packets within the next 12 hours since the current time.

Packets Discard

Report

Outgoing packets are dropped on an interface.

More than 10 outgoing packets are dropped on the interface because the outgoing traffic volume exceeds the buffer.

If more than 10 outgoing packets are dropped on the interface for the first time, an event is recorded, and the Discard_Number attribute is set to Abnormal. If the number of dropped outgoing packets remains unchanged within 12 hours, the Discard_Number attribute is restored to Normal. If the number of dropped outgoing packets increases within 12 hours, the system checks whether the number of dropped outgoing packets increases within the next 12 hours since the current time.

Burst Traffic

Report

There is burst traffic.

An interface uses dynamic buffer.

If there is burst traffic within multiple consecutive periods, an event is recorded only for the first time.

Table 7-41  OIDS events supported by the TEMP diagnosis type

Event

Type

Description

Reason

Suppression

Temperature High

Warning

Sensor temperature is high.

Sensor temperature exceeds the threshold. To learn about the high temperature alarm threshold of each board, run the display temperature command.

None

Temperature Normal

Recovery

Sensor temperature returns to the normal range.

Sensor temperature returns to the normal range. To learn about the high temperature alarm clear threshold of each board, run the display temperature command.

None

Translation
Download
Updated: 2018-09-03

Document ID: EDOC1100038289

Views: 37068

Downloads: 15

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next