Configuration Guide - Device Management

S9300, S9300E, and S9300X V200R012C00

This document describes the configurations of Device Management, including device status query, hardware management, CSS, SVF, PoE, OPS, OIDS, energy-saving management, information center, fault management, NTP, synchronous ethernet, PTP.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring Fan Speed Adjustment

Configuring Fan Speed Adjustment

Context

The device adjusts fan speed by monitoring the optical module temperature on the board. When the temperature of an optical module exceeds the upper threshold, the fan speed increases. When the temperature of optical modules falls below the lower threshold, the fan speed is reduced.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run set transceiver temperature threshold low-temperature high-temperature { all | slot slot-id }

    The upper and lower temperature thresholds for fan speed adjustment are configured.

    By default, the fan speed is reduced when the temperature falls below 60°C and is increased when the temperature exceeds 65°C.

    NOTE:
    The following boards do not support this function:
    • SC series boards, including: LE1D2X08SSC0, LE1D2X12SSC0, LE1D2X16SSC2, LE1D2X32SSC0
    • X2E series boards, including: LE1D2S24SX2E, LE1D2S16SX2E, LE1D2X32SX2E, LE1D2L08QX2E, LE1D2C04HX2E, LE1D2H02QX2E, LE1D2L08QX2E
    • X2S series boards, including: LE1D2S24SX2S, LE1D2S16SX2S, LE1D2X32SX2S, LE1D2X24SX2S, LE1D2X48SX2S, LE1D2C04HX2S, LE1D2H02QX2S
    • X2L series boards, including: LE3D2X22SX2L

Verifying the Configuration

  • Run the display transceiver temperature threshold { current | default } slot slot-id command to check the upper and lower temperature thresholds of the fan module.

  • Run the display fan command to check the fan status.