This document describes the configuration of Ethernet services, including configuring MAC address table, link aggregation, VLANs, VLAN aggregation, MUX VLAN, VLAN termination, Voice VLAN, VLAN mapping, QinQ, GVRP, STP/RSTP/MSTP, VBST, SEP, RRPP, ERPS, LBDT, HVRP, and Layer 2 protocol transparent transmission.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Eth-Trunk at Both Ends Cannot Be Up Because the Lower Threshold for the Number of Active Interfaces Is Incorrect

Eth-Trunk at Both Ends Cannot Be Up Because the Lower Threshold for the Number of Active Interfaces Is Incorrect

Fault Description

The Eth-Trunk is Down because the lower threshold for the number of active interfaces is incorrect.

Procedure

  1. Run the display eth-trunk trunk-id command to check whether the lower threshold for the number of active interfaces of an Eth-Trunk is set.

    If the number of Eth-Trunk member interfaces in Up state is lower than the lower threshold, the Eth-Trunk becomes Down.

  2. Run the least active-linknumber link-number command to configure the lower threshold for the number of active interfaces of an Eth-Trunk to be smaller than the number of Eth-Trunk member interfaces in Up state.

    The local and remote devices can be configured with different lower thresholds for the number of active interfaces. If the lower thresholds are different, a larger value becomes effective.