Configuration Guide - Ethernet Switching

S1720, S2700, S5700, and S6720 V200R012(C00 and C20)

This document describes the configuration of Ethernet services, including configuring MAC address table, link aggregation, VLANs, VLAN aggregation, MUX VLAN, VLAN termination, Voice VLAN, VLAN mapping, QinQ, GVRP, VCMP, STP/RSTP/MSTP, VBST, SEP, RRPP, ERPS, LBDT, and Layer 2 protocol transparent transmission.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Licensing Requirements and Limitations for ERPS

Licensing Requirements and Limitations for ERPS

Involved Network Elements

Other network elements are required to support ERPS functions.

Licensing Requirements

ERPS is a basic feature of a switch and is not under license control.

Version Requirements

Table 18-6  Products and versions supporting ERPS

Product

Product Model

Software Version

S2700

S2700SI

Not supported

S2700EI

V100R005C01, V100R006(C00&C01&C03&C05)

S2710SI

Not supported

S2720EI

V200R006C10, V200R009C00, V200R010C00, V200R011C10, V200R012C00

S2750EI

V200R003C00, V200R005C00SPC300, V200R006C00, V200R007C00, V200R008C00, V200R009C00, V200R010C00, V200R011C00, V200R011C10, V200R012C00

S3700

S3700SI

Not supported

S3700EI

Not supported

S3700HI

V200R001C00

S5700

S5700LI

V200R001C00, V200R002C00, V200R003(C00&C02&C10), V200R005C00SPC300, V200R006C00, V200R007C00, V200R008C00, V200R009C00, V200R010C00, V200R011C00, V200R011C10, V200R012C00

S5700S-LI

Not supported

S5710-C-LI

V200R001C00

S5710-X-LI

V200R008C00, V200R009C00, V200R010C00, V200R011C00, V200R011C10, V200R012C00

S5700SI

V200R001C00, V200R002C00, V200R003C00, V200R005C00

S5700EI

V200R001(C00&C01), V200R002C00, V200R003C00, V200R005(C00&C01&C02&C03)

S5710EI

V200R001C00, V200R002C00, V200R003C00, V200R005(C00&C02)

S5720EI

V200R007C00, V200R008C00, V200R009C00, V200R010C00, V200R011C00, V200R011C10, V200R012C00

S5700HI

V200R001(C00&C01), V200R002C00, V200R003C00, V200R005(C00&C01&C02)

S5710HI

V200R003C00, V200R005(C00&C02&C03)

S5720HI

V200R006C00, V200R007(C00&C10), V200R008C00, V200R009C00, V200R010C00, V200R011C00, V200R011C10, V200R012C00

S5730HI

V200R012C00

S5720LI, S5720S-LI

V200R010C00, V200R011C00, V200R011C10, V200R012(C00&C20)

S5720SI, S5720S-SI

V200R008C00, V200R009C00, V200R010C00, V200R011C00, V200R011C10, V200R012C00

S5720I-SI

V200R012C00

S5730SI

V200R011C10, V200R012C00

S5730S-EI

V200R011C10, V200R012C00

S6700

S6700EI

V200R001(C00&C01), V200R002C00, V200R003C00, V200R005(C00&C01&C02)

S6720EI

V200R008C00, V200R009C00, V200R010C00, V200R011C00, V200R011C10, V200R012C00

S6720S-EI

V200R009C00, V200R010C00, V200R011C00, V200R011C10, V200R012C00

S6720LI, S6720S-LI

V200R011C00, V200R011C10, V200R012C00

S6720SI, S6720S-SI

V200R011C00, V200R011C10, V200R012C00

S6720HI

V200R012C00

NOTE:

For details about software mappings, visit Hardware Query Tool and search for the desired product model.

For feature support of S1700 series switches, see S1700 Series Enterprise Switches - Specifications.

Feature Limitations

  • V200R002 and earlier versions support only ERPSv1.
  • Before adding a port to an ERPS ring, ensure that port security has been disabled on the port. Otherwise, loops cannot be eliminated.
  • Before adding a port to an ERPS ring, ensure that the Spanning Tree Protocol (STP), Rapid Ring Protection Protocol (RRPP), Smart Ethernet Protection (SEP), or Smart Link is not enabled on the port.
  • The service loopback function and ERPS cannot be configured on an Eth-Trunk simultaneously.

  • The S6700EI does not support association between an ERPS interface and Ethernet CFM.