This document describes the configuration of Ethernet services, including configuring MAC address table, link aggregation, VLANs, VLAN aggregation, MUX VLAN, VLAN termination, Voice VLAN, VLAN mapping, QinQ, GVRP, VCMP, STP/RSTP/MSTP, VBST, SEP, RRPP, ERPS, LBDT, and Layer 2 protocol transparent transmission.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Creating a LAG

Creating a LAG

Context

Each LAG has one logical interface, that is, an Eth-Trunk. Before configuring link aggregation, create an Eth-Trunk.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run interface eth-trunk trunk-id

    An Eth-Trunk is created and the Eth-Trunk interface view is displayed.

    If the specified Eth-Trunk already exists, this command directly displays the Eth-Trunk interface view.

    trunk-id defines the Eth-Trunk ID. The following is the value range of trunk-id for different models:
    • S1720GFR-TP, S2750EI, S5700LI, S5700S-LI, and S5710-X-LI: 0-63
    • S1720GF, S1720GFR-P, S1720GW, S1720GWR, S1720GW-E, S1720GWR-E, S2720EI, S5720I-SI, S5720SI, S5720LI, S5720S-LI, and S5720S-SI: 0-119
    • S5720EI, S5720HI, S5730HI, S6720EI, S6720HI, and S6720S-EI: 0-127
    • S1720X, S1720X-E, S5730SI, S5730S-EI, S6720SI, S6720S-SI, S6720LI, and S6720S-LI: 0-249

    On the S6720EI, and S6720S-EI, you can run the assign trunk command to set the value, and run the display trunk configuration command to check the configuration.