No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

CloudEngine 12800 and 12800E V200R005C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
SYSTEM_1.3.6.1.4.1.2011.5.25.219.2.11.1 hwSystemConfigError

SYSTEM_1.3.6.1.4.1.2011.5.25.219.2.11.1 hwSystemConfigError

Description

A system configuration error occurs. ( EntityTrapFaultID = [EntityTrapFaultID])

The system configuration was incorrect.

This trap is supported only on the Admin-VS.

Attributes

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwSystemConfigError

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.11.1

Alarm ID

0x0d300004

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

SYSTEM_1.3.6.1.4.1.2011.5.25.219.2.11.2 hwSystemConfigResume

Parameters

Parameter Description

EntityTrapFaultID

Trap error codes.
  • EntityTrapFaultID=144130 indicates that the package versions of the master and slave boards were inconsistent.
  • EntityTrapFaultID=144133 indicates that the memory of the master and slave boards were inconsistent.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

N/A

Impact on the System

  • The slave board cannot be activated when the package versions of the master and slave boards are inconsistent.
  • The master/slave main control board switchover may fail if the memory on the master main control board is inconsistent with that on the slave main control board.

Possible Causes

Cause 144130: The package versions of the master and slave boards were inconsistent.

Cause 144133: The memory of the master and slave boards were inconsistent.

Procedure

  • Cause 144130: The package versions of the master and slave boards were inconsistent.
    1. Run the startup system-software command to configure the slave board version to be consistent with the master board version. Run the reset slot command to reset the slave board. Wait for a period of time, and then check whether the alarm is cleared.

      • If yes, go to Step 3.
      • If No, go to Step 2.

    2. Collect alarm information and configuration information, and then contact technical support personnel.
    3. End.