Alarm Handling

CloudEngine 12800 and 12800E V200R005C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.48 hwStackMemberPortProtocolAlarmResume

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.48 hwStackMemberPortProtocolAlarmResume

Description

The physical status and protocol status of the stack member port is up or down at the same time, or the stack member port is deleted. (hwStackLocalIfName=[hwStackLocalIfName])

The physical status and protocol status of the stack member port are both Up or Down, or the stack configuration is removed from the port.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwStackMemberPortProtocolAlarmResume

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.48

Alarm ID

0x09a22023

Alarm Type

communicationsAlarm

Raise or Clear

Clear

Match trap

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.47 hwStackMemberPortProtocolAlarm

Parameters

Name Meaning

hwStackLocalIfName

Indicates the name of the stack member port.

VB Parameters

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.32.1

hwStackLocalIfName

N/A

Impact on the System

None

Possible Causes

The link fault of the stack member port is rectified, or the stack configuration is removed from the port.

Procedure

  1. This trap message is informational only, and no action is required.