Alarm Handling

CloudEngine 12800 and 12800E V200R005C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
PTP_1.3.6.1.4.1.2011.5.25.187.5.2 hwPtpClockSourceChange

PTP_1.3.6.1.4.1.2011.5.25.187.5.2 hwPtpClockSourceChange

Description

Time source changed. (hwPtpOldMasterClockId=[hwPtpOldMasterClockId],hwPtpCurrentMasterClockId=[hwPtpCurrentMasterClockId],hwPtpPortIfIndex= [hwPtpPortIfIndex], hwPtpPortOldSourcePortNum = [hwPtpPortOldSourcePortNum], hwPtpPortSourcePortNum = [hwPtpPortSourcePortNum], hwPtpOldPortName = [hwPtpOldPortName], hwPtpPortName = [hwPtpPortName])

The clock source changed.

Attributes

Attribute

Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

hwPtpClockSourceChange

Trap OID

1.3.6.1.4.1.2011.5.25.187.5.2

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the matching trap.

Parameters

Parameter Description

hwPtpOldMasterClockId

ID of the old master clock.

hwPtpCurrentMasterClockId

ID of the current master clock.

hwPtpNewIfIndex

New clock source index.

hwPtpPortOldSourcePortNum

Port number of the old clock source.

hwPtpPortSourcePortNum

Port number of the current clock source.

hwPtpOldPortName

Port name of the old clock source.

hwPtpPortName

Port name of the current clock source.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.187.1.14

hwPtpOldMasterClockId

N/A

1.3.6.1.4.1.2011.5.25.187.1.32

hwPtpCurrentMasterClockId

N/A

1.3.6.1.4.1.2011.5.25.187.2.1.1.47

hwPtpPortOldSourcePortNum

hwPtpPortIfIndex

1.3.6.1.4.1.2011.5.25.187.2.1.1.30

hwPtpPortSourcePortNum

hwPtpPortIfIndex

1.3.6.1.4.1.2011.5.25.187.2.1.1.48

hwPtpOldPortName

hwPtpPortIfIndex

1.3.6.1.4.1.2011.5.25.187.2.1.1.43

hwPtpPortName

hwPtpPortIfIndex

Impact on the System

Services will not be affected.

Possible Causes

Cause 1: Clock attributes of the device were changed, leading to the master clock switchover.

Cause 2: The link was faulty or an interface went Down, leading to the master clock switchover.

Procedure

  1. Run the display ptp all command in any view to check whether any interface is faulty.

    • If an interface is faulty, the link is faulty or the interface is Down. Rectify this fault and go to step 4.

    • If no interface is faulty, go to step 2.

  2. Run the display this interface and display ptp all config commands in the interface view to check whether the clock attributes of the device and interface were changed.

    • If so, restore the previous clock attributes and go to step 4.

    • If not, go to step 3.

  3. Collect alarm information, log information, and configuration of the device, and contact technical support.
  4. End.