Alarm Handling

CloudEngine 12800 and 12800E V200R005C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
OPENFLOW_1.3.6.1.4.1.2011.5.25.344.2.2 hwOpenflowConnectionDownClear

OPENFLOW_1.3.6.1.4.1.2011.5.25.344.2.2 hwOpenflowConnectionDownClear

Description

Openflow connection status changes. (IP Type=[OpenflowIpType], Local IP=[OpenflowLocalIp], Remote IP=[OpenflowRemoteIp], VrfName=[VrfName], DatapathId=[DatapathId], AuxiliaryId=[AuxiliaryId], SubReason=[SubReason], Reason=[Reason])

The OpenFlow connection was restored.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwOpenflowConnectionDownClear

Trap OID

1.3.6.1.4.1.2011.5.25.344.2.2

Alarm ID

0x00F1007c

Alarm Type

communicationsAlarm

Raise or Clear

Clear

Match trap

OPENFLOW_1.3.6.1.4.1.2011.5.25.344.2.1 hwOpenflowConnectionDown

Parameters

Parameter Description

IP Type

Type of an IP address

Local IP

IP address of a forwarder of an OpenFlow connection

Remote IP

IP address of a controller of an OpenFlow connection

VrfName

Index of a VRF instance in which an OpenFlow connection is established

DatapathId

ID of an OpenFlow forwarder

AuxiliaryId

Auxiliary connection ID

SubReason

Reason why an OpenFlow connection was interrupted

Reason

Reason why an OpenFlow session went Down

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.344.1.2.1.1.1

hwOpenflowIpType

hwOpenflowIpType

hwOpenflowRemoteIp

hwOpenflowLocalIp

hwOpenflowVpnInstanceName

hwOpenflowDatapathId

hwOpenflowAuxiliaryId

1.3.6.1.4.1.2011.5.25.344.1.2.1.1.2

hwOpenflowRemoteIp

hwOpenflowIpType

hwOpenflowRemoteIp

hwOpenflowLocalIp

hwOpenflowVpnInstanceName

hwOpenflowDatapathId

hwOpenflowAuxiliaryId

1.3.6.1.4.1.2011.5.25.344.1.2.1.1.3

hwOpenflowLocalIp

hwOpenflowIpType

hwOpenflowRemoteIp

hwOpenflowLocalIp

hwOpenflowVpnInstanceName

hwOpenflowDatapathId

hwOpenflowAuxiliaryId

1.3.6.1.4.1.2011.5.25.344.1.2.1.1.4

hwOpenflowVpnInstanceName

hwOpenflowIpType

hwOpenflowRemoteIp

hwOpenflowLocalIp

hwOpenflowVpnInstanceName

hwOpenflowDatapathId

hwOpenflowAuxiliaryId

1.3.6.1.4.1.2011.5.25.344.1.2.1.1.5

hwOpenflowDatapathId

hwOpenflowIpType

hwOpenflowRemoteIp

hwOpenflowLocalIp

hwOpenflowVpnInstanceName

hwOpenflowDatapathId

hwOpenflowAuxiliaryId

1.3.6.1.4.1.2011.5.25.344.1.2.1.1.6

hwOpenflowAuxiliaryId

hwOpenflowIpType

hwOpenflowRemoteIp

hwOpenflowLocalIp

hwOpenflowVpnInstanceName

hwOpenflowDatapathId

hwOpenflowAuxiliaryId

1.3.6.1.4.1.2011.5.25.344.1.2.1.1.7

hwOpenflowConnectionDownSubReason

hwOpenflowIpType

hwOpenflowRemoteIp

hwOpenflowLocalIp

hwOpenflowVpnInstanceName

hwOpenflowDatapathId

hwOpenflowAuxiliaryId

1.3.6.1.4.1.2011.5.25.344.1.2.1.1.8

hwOpenflowConnectionDownReason

hwOpenflowIpType

hwOpenflowRemoteIp

hwOpenflowLocalIp

hwOpenflowVpnInstanceName

hwOpenflowDatapathId

hwOpenflowAuxiliaryId

Impact on the System

Services will not be affected.

Possible Causes

The OpenFlow connection was restored.

Procedure

  • This trap message is informational only, and no action is required.