No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

CloudEngine 12800 and 12800E V200R005C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
DEVM_1.3.6.1.4.1.2011.5.25.219.2.5.1 hwPowerRemove

DEVM_1.3.6.1.4.1.2011.5.25.219.2.5.1 hwPowerRemove

Description

The power module was removed. (EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=[EntityTrapFaultID], Reason=[Reason])

A power module was removed.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwPowerRemove

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.5.1

Alarm ID

0x0813001f

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.5.2 hwPowerInsert

Parameters

Name Meaning

EntPhysicalIndex

Indicates the index of an entity.

EntPhysicalName

Indicates the name of an entity.

EntityTrapFaultID

Indicates the error code: 136448.

Reason

Indicates a possible cause.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

N/A

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

N/A

Impact on the System

The power module is removed, which may cause insufficient power supply. If the power supply is insufficient, the board may be powered off. This affects services. This fault needs to be rectified.

Possible Causes

A power module was removed.

Procedure

  1. Check whether the power module is installed.
  2. If so, check whether the power module is installed correctly.
  3. If the power module is installed correctly but the fault persists, replace the power module.
  4. If the fault persists after the power module is replaced, collect traps, logs, and configurations, and contact technical support personnel.
Translation
Download
Updated: 2019-04-20

Document ID: EDOC1100039527

Views: 87747

Downloads: 21

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share