Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
OSPFV3_1.3.6.1.2.1.191.0.10 ifstatechange

OSPFV3_1.3.6.1.2.1.191.0.10 ifstatechange

Description

The status of the non-virtual interface changes. (RouterId=[RouterId], IfIndex=[IfIndex], IfInstId=[IfInstId], IfState=[IfState], InterfaceName=[InterfaceName], ChgReason=[ChgReason])

An OSPFv3 packet that could not be parsed was received from a non-virtual interface. The possible cause is that the local device was attacked or the local device failed to connect to a non-Huawei device.

Attributes

Attribute

Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

ifstatechange

Trap OID

1.3.6.1.2.1.191.0.10

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the matching trap.

Parameters

Parameter Description

RouterId

Indicates the router ID.

IfIndex

Indicates the interface index.

IfInstId

Indicates the instance ID.

IfState

Indicates the interface status.

  • 1: Down
  • 2: Attempt
  • 3: Init
  • 4: 2–Way
  • 5: Exstart
  • 6: Exchange
  • 7: Loading
  • 8: Full

InterfaceName

Indicates the interface name.

ChgReason

Indicates the reason of the change of the interface status.

VB

VB OID

VB Name

VB Index

1.3.6.1.2.1.191.1.1.1

ospfv3RouterId

N/A

1.3.6.1.2.1.191.1.7.1.12

ospfv3IfState

ospfv3IfIndex;

ospfv3IfInstId;

Impact on the System

This trap message is generated when the status of a common interface changes from a lower status to Full or from a higher status to a lower status. This trap message may affect the neighbor status. If the interface goes to a lower status such as Down, the neighbor relationship will be interrupted.

Possible Causes

Cause 1: The physical interface was in the Down state.

Cause 2: An OSPFv3 neighbor relationship was being established.

Procedure

  1. Run the display ospfv3 interface command to check whether the interface status is Up.

    • If the status is Up, go to step 3.

    • If the status is not Up, go to step 2.

  2. Collect the alarm information, log information, and configuration information, and then contact technical support personnel technical support personnel.
  3. End.
Translation
Download
Updated: 2019-04-20

Document ID: EDOC1100039527

Views: 90564

Downloads: 21

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next