Alarm Handling

CloudEngine 12800 and 12800E V200R005C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
DEVM_1.3.6.1.4.1.2011.5.25.219.2.33.3 hwPduCommLost

DEVM_1.3.6.1.4.1.2011.5.25.219.2.33.3 hwPduCommLost

Description

The communication of PDU is lost.(EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=[EntityTrapFaultID], Reason=[Reason])

Communication with the PDU is lost.

Attributes

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwPduCommLost

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.33.3

Alarm ID

0x0813220c

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.33.4 hwPduCommLostResume

Parameters

Parameter Name Parameter Meaning
EntPhysicalIndex Indicates the entity index.
EntPhysicalName Indicates the entity name.
EntityTrapFaultID Indicates the error code.
  • 149760
  • 149761
Reason Indicates a possible cause.

VB Parameters

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

N/A

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

N/A

Impact on the System

The PDU may fail to work.

Possible Causes

  • Cause 1 (EntityTrapFaultID=[149760]): The active MPU and PDU cannot communicate with each other.

  • Cause 2 (EntityTrapFaultID=[149761]): The standby MPU and PDU cannot communicate with each other.

Procedure

  1. Cause 1: The active MPU and PDU cannot communicate with each other.
    1. Check whether the MPU and PDU are installed properly. If not, install them properly.
  2. Cause 2: The standby MPU and PDU cannot communicate with each other.
    1. Check whether the MPU and PDU are installed properly. If not, install them properly.