No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

CloudEngine 12800 and 12800E V200R005C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
MACSEC_1.3.6.1.4.1.2011.5.25.347.2.2 hwMacsecCknSwitchFail

MACSEC_1.3.6.1.4.1.2011.5.25.347.2.2 hwMacsecCknSwitchFail

Description

Failed to switch the CKN(IfIndex=[IfIndex], Role=[Role], Local Port=[LocalPort], Old CKN=[OldCKN],New CKN=[NewCKN], Switch Reason=[SwitchReason], Failed Reason=[FailReason])

If the CKN switchover fails or the switchover is not complete three minutes later, an alarm is generated.

Attributes

Attribute

Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

hwMacsecCknSwitchFail

Trap OID

1.3.6.1.4.1.2011.5.25.347.2.2

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the matching trap.

Parameters

Parameter Description

IfIndex

Interface index

Role

Device role

LocalPort Local interface
OldCKN Original CKN
NewCKN Newly configured CKN
SwitchReason CKN switching cause
  • Manual configuration
FailReason CKN switchover failure cause

VB Parameters

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.347.1.1.1.2

hwMACsecPortRole

hwMACsecIfIndex

1.3.6.1.4.1.2011.5.25.347.1.1.1.3

hwMACsecPortName

hwMACsecIfIndex

1.3.6.1.4.1.2011.5.25.347.1.1.1.4 hwMACsecPortOldCKN hwMACsecIfIndex
1.3.6.1.4.1.2011.5.25.347.1.1.1.5 hwMACsecPortNewCKN hwMACsecIfIndex
1.3.6.1.4.1.2011.5.25.347.2.1.1 hwMACsecCKNSwitchReason N/A
1.3.6.1.4.1.2011.5.25.347.2.1.2 hwMACsecCKNSwitchFailReason N/A

Impact on the System

None

Possible Causes

Cause 1: The CAK configurations on the two ends are inconsistent.

Cause 2: The peer end does not respond.

Procedure

  • Cause 1: The CAK configurations on the two ends are inconsistent.
    1. Run the mka cak-mode static ckn ckn cak cak command in the interface view to configure the same CAK. Check whether the alarm is cleared.

      • If the alarm is cleared, no further action is required.
      • If the alarm persists, go to step 2.

    2. Collect the alarm, log, and configuration information, and contact Huawei technical support personnel.
  • Cause 2: The peer end does not respond.
    1. Run the display mka interface interface-type interface-number command in any view to check whether the peer device supports the MACsec function.

      • If the peer device does not support the MACsec function, the function is not available and does not need to be configured.
      • If the peer device supports MACsec, go to Step 2.

    2. Run the display interface command in any view to check the interface status on both devices.

      • If the interfaces on both ends are Up, the device re-negotiates with the peer device, and no action is required.
      • If one or both interfaces are Down, run the undo shutdown command in the interface view to configure both interfaces to go Up. If the alarm persists, go to Step 3.

    3. Collect the alarm, log, and configuration information, and contact Huawei technical support personnel.