Alarm Handling

CloudEngine 12800 and 12800E V200R005C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
SMLKTRAP_1.3.6.1.4.1.2011.5.25.42.5.2.2 hwSmartLinkInactiveLinkFail

SMLKTRAP_1.3.6.1.4.1.2011.5.25.42.5.2.2 hwSmartLinkInactiveLinkFail

Description

[LinkStatus] link port [IfIndex] of smart link group [SmlkGrpID] was abnormal.

A member interface in a Smart Link group was faulty.

Attribute

Attribute Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwSmartLinkInactiveLinkFail

Trap OID

1.3.6.1.4.1.2011.5.25.42.5.2.2

Alarm ID

0x09c72000

Alarm Type

communicationsAlarm

Raise or Clear

Raise

Match trap

SMLK_1.3.6.1.4.1.2011.5.25.42.5.2.3 hwSmartLinkInactiveLinkResume

Parameters

Parameter Description
LinkStatus Indicates the status of a link.
IfIndex Indicates the index of an interface.
SmlkGrpID Indicates the ID of a Smart Link group that an interface belongs.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.42.5.1.9.1.3

hwSmartLinkPcIfIndex

hwSmartLinkPcIfIndex

Impact on the System

The inactive interface is faulty, and no link switchover can be performed.

Possible Causes

Cause: The inactive interface is down.

Procedure

  • The inactive interface is down.
    1. Run the display interface brief command to check the physical status of the inactive interface.
    2. Check whether the cable of the inactive link is correctly connected.

      • If the inactive interface is Up, and the cable is correctly connected, go to Step 3.

      • If the inactive interface goes Down, and the undo shutdown command does not set the interface to Up, go to Step 3.

    3. Collect trap, log, and configuration information, and contact technical support personnel.