Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
DEVM_1.3.6.1.4.1.2011.5.25.219.2.2.1 hwBoardRemove

DEVM_1.3.6.1.4.1.2011.5.25.219.2.2.1 hwBoardRemove

Description

The board was removed. (EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityType=[EntityType], EntityTrapFaultID=[EntityTrapFaultID], Reason=[Reason])

A board was removed.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwBoardRemove

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.2.1

Alarm ID

0x08130040

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.2.2 hwBoardInsert

Parameters

Name Meaning

EntPhysicalIndex

Indicates the index of an entity.

EntPhysicalName

Indicates the name of an entity.

EntityType

Indicates the entity type.
  • 1: MPU
  • 2: LPU
  • 3: SFU
  • 4: subcard
  • 5: storage medium

EntityTrapFaultID

Indicates the error code: 131840.

Reason

Indicates a possible cause.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

N/A

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.2

hwEntityTrapEntType

N/A

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

N/A

Impact on the System

Services on the board were interrupted, affecting reliable transmission of control data between devices.

Possible Causes

A board was removed.

Procedure

  1. Check whether the board was removed manually.

    • If so, no action is required.

    • If not, go to step 2.

  2. Install the board. After the board is started successfully, run the display device [ slot slot-id ] command to check whether the board is registered successfully.

    • If so, the fault is rectified.

    • If not, go to step 2.

  3. Collect traps, logs, and configurations, and contact technical support personnel.