Alarm Handling

CloudEngine 12800 and 12800E V200R005C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.57 hwStackSipPortSingleLinkAlarm

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.57 hwStackSipPortSingleLinkAlarm

Description

There is only one available link between SIP ports in the out-of-band CSS.(hwStackMemberId=[hwStackMemberId])

There is only one Up SIP link between two stack member switches.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwStackSipPortSingleLinkAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.57

Alarm ID

0x0a762003

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.58 hwStackSipPortSingleLinkAlarmResume

Parameters

Name Meaning

hwStackMemberId

Stack member ID

VB Parameters

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.32.10

hwStackMemberId

N/A

Impact on the System

The stack has low reliability.

Possible Causes

In a stack set up using MPUs, there is only one Up SIP link between two stack member switches.

Procedure

  1. Increase SIP links or restore unavailable SIP links to ensure that there are two or more Up SIP links.