Alarm Handling

CloudEngine 12800 and 12800E V200R005C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ETRUNK_1.3.6.1.4.1.2011.5.25.178.8.2.1 hwMLagConsistencyCheckType1

ETRUNK_1.3.6.1.4.1.2011.5.25.178.8.2.1 hwMLagConsistencyCheckType1

Description

The two switches in the M-LAG have different [typeName] configurations.

The key configuration of M-LAG master and backup devices is inconsistent.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwMLagConsistencyCheckType1

Trap OID

1.3.6.1.4.1.2011.5.25.178.8.2.1

Alarm ID

0x0ae52004

Alarm Type

communicationsAlarm

Raise or Clear

Raise

Match trap

ETRUNK_1.3.6.1.4.1.2011.5.25.178.8.2.2 hwMLagConsistencyCheckType1Resume

Parameters

Name

Meaning

[typeName]

Indicates the configuration type. The value must be type1.

VB parameters

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.178.8.2.1

hwMLagConsistencyType1

hwMLagObjects 1

Impact on the System

If the key configuration of M-LAG master and backup devices is inconsistent, problems may occur, for examples, loops may occur or packets are lost though the M-LAG status is normal.

Possible Causes

The key configuration of the local or remote device is inconsistent.

Procedure

  • Run the display dfs-group consistency-check { global | interface m-lag m-lag-id } command to check the configuration of M-LAG master and slave devices. Then adjust the deployment based on the check result until the key configuration consistency check succeeds.