Alarm Handling

CloudEngine 12800 and 12800E V200R005C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
EFM_1.3.6.1.4.1.2011.5.25.136.1.6.8 dyinggasp

EFM_1.3.6.1.4.1.2011.5.25.136.1.6.8 dyinggasp

Description

Remote DyingGasp Event occurred. (IfIndex=[INTEGER], RemoteMacAddress=[OCTET], IfName=[OCTET])

An unrecoverable event occurs, for example, the system or a board restarts, or the device is powered off.

Attributes

Attribute

Description

Alarm or Event

Event

Trap Severity

Error

Mnemonic Code

dyinggasp

Trap OID

1.3.6.1.4.1.2011.5.25.136.1.6.8

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the matching trap.

Parameters

Parameter

Description

IfIndex Interface index of the peer device received by the local device
RemoteMacAddress MAC address of the remote device
IfName Interface name of the peer device received by the local device

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.136.1.2.2.3.1.1

hwDot3ahEfmPeerMacAddress

ifIndex

1.3.6.1.2.1.2.2.1.2

None

ifDescr

Impact on the System

Services on the remote device are unavailable.

Possible Causes

Cause 1:

The remote device restarts.

Cause 2:

The board on the remote device restarts.

Cause 3:

The remote device is powered off.

Procedure

  1. After the remote device or the board on the remote device restarts, run the display efm session command to check the EFM status.

    • If yes, go to Step 3.
    • If no, go to Step 2.

  2. Collect configuration, trap messages, and log messages, and then contact technical personnel.
  3. End.