Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
PIM-STD_1.3.6.1.2.1.157.0.4 pimrpmappingchange

PIM-STD_1.3.6.1.2.1.157.0.4 pimrpmappingchange

Description

The RP changes. (GroupMappingOrigin=[GroupMappingOrigin], GroupMappingAddressType=[GroupMappingAddressType], szGrpAddr=[szGrpAddr], GrpPfxLen=[GrpPfxLen], GroupMappingRPAddressType=[GroupMappingRPAddressType], RPAddr=[RPAddr], GroupMappingPimMode=[GroupMappingPimMode], Precedence=[Precedence])

The RP changed.

Attributes

Attribute

Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

pimrpmappingchange

Trap OID

1.3.6.1.2.1.157.0.4

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the matching trap.

Parameters

Parameter Description

GroupMappingOrigin

RP type

GroupMappingAddressType

Group address type

szGrpAddr

Group address

GrpPfxLen

Mask length of the group address

GroupMappingRPAddressType

RP address type

RPAddr

New RP address

GroupMappingPimMode

Current PIM mode

Precedence

Precedence of different types of RPs

VB

VB OID

VB Name

VB Index

1.3.6.1.2.1.157.1.13.1.7

pimGroupMappingPimMode

pimGroupMappingOrigin;

pimGroupMappingAddressType;

pimGroupMappingGrpAddress;

pimGroupMappingGrpPrefixLength;

pimGroupMappingRPAddressType;

pimGroupMappingRPAddress;

1.3.6.1.2.1.157.1.13.1.8

pimGroupMappingPrecedence

pimGroupMappingOrigin;

pimGroupMappingAddressType;

pimGroupMappingGrpAddress;

pimGroupMappingGrpPrefixLength;

pimGroupMappingRPAddressType;

pimGroupMappingRPAddress;

Impact on the System

The change of the RP causes the source and multicast members fail to communicate. This will adversely affect multicast services.

Possible Causes

Cause1: A static RP was reconfigured and the preferred parameter was configured to preferentially select the static RP.

Cause2: A C-RP with a higher priority than the existing ones existed.

Procedure

  • Cause1: A static RP was reconfigured and the preferred parameter was configured to preferentially select the static RP.
    1. Check whether RP information is changed manually.

      • If so, go to Step 5.

      • If not, go to Step 2.

    2. Run the static-rp rp-address preferred command in the PIM view to configure the original RP as a static RP on every . The static RP is preferred. Then, go to Step 3.
    3. Run the display pim rp-info group-address command to check whether RP information meets requirements.

      • If so, go to Step 5.

      • If not, go to Step 4.

    4. Collect the alarm information, log information, and configuration information, and then contact technical support personnel.
    5. End.
  • Cause2: A C-RP with a higher priority than the existing ones existed.
    1. Check whether RP information is changed manually.

      • If so, go to Step 5.

      • If not, go to Step 2.

    2. Run the c-rp priority priority or c-rp interface-type interface-number priority priority command in the PIM view to reduce the priority value of the C-RP, that is, increase the priority of the C-RP on the that is expected to serve as the RP. Then, go to Step 3.
    3. Run the display pim rp-info group-address command to check whether RP information meets requirements.

      • If so, go to Step 5.

      • If not, go to Step 4.

    4. Collect the alarm information, log information, and configuration information, and then contact technical support personnel.
    5. End.