Alarm Handling

CloudEngine 12800 and 12800E V200R005C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
DEVM_1.3.6.1.4.1.2011.5.25.219.2.5.5 hwPowerInvalid

DEVM_1.3.6.1.4.1.2011.5.25.219.2.5.5 hwPowerInvalid

Description

A power module experienced a complete failure. (EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=[EntityTrapFaultID], Reason=[Reason])

The power module completely failed.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwPowerInvalid

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.5.5

Alarm ID

0x0813001b

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.5.6 hwPowerInvalidResume

Parameters

Name Meaning

EntPhysicalIndex

Indicates the index of an entity.

EntPhysicalName

Indicates the name of an entity.

EntityTrapFaultID

Indicates the error code.
  • 136962

  • 136963

  • 136966

  • 136968

  • 136964

  • 136983

Reason

Indicates a possible cause.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

N/A

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

N/A

Impact on the System

A fault of the power module may cause insufficient power supply on the device. As a result, boards will be reset. Services are affected. This fault needs to be rectified.

Possible Causes

  • Cause 1 (EntityTrapFaultID=[136962]): Input overvoltage occurred on the power module.

  • Cause 2 (EntityTrapFaultID=[136963]): Input undervoltage occurred on the power module.

  • Cause 3 (EntityTrapFaultID=[136966]): The power module was installed but not powered on.

  • Cause 4 (EntityTrapFaultID=[136968]): Output overvoltage occurred on the power module.

  • Cause 5 (EntityTrapFaultID=[136964]): Over-temperature occurred on the power module.

  • Cause 6 (EntityTrapFaultID=[136983]): The power module is in overtemperature protection state.

Procedure

  • Cause 1: Input overvoltage occurred on the power module.
    1. Check whether the external power supply is proper. If not, repair the external circuit.
    2. If the fault persists, replace the power module.
  • Cause 2: Input undervoltage occurred on the power module.
    1. Check whether the external power supply is proper. If not, repair the external circuit.
    2. If the fault persists, replace the power module.
  • Cause 3: The power module was installed but not powered on.
    1. Power on the power module.
  • Cause 4: Output overvoltage occurred on the power module.
    1. Check whether the external power supply is proper. If not, repair the external circuit.
    2. If the fault persists, replace the power module.
  • Cause 5: Over-temperature occurred on the power module.
    1. Check whether the fan of the power module cannot work because the air filter is clogged. If so, clean the air filter.
    2. Check whether the ambient temperature is within the allowed range. If the temperature is too high, improve heat dissipation.
    3. Check whether the power supply is normal. If not, repair the external power supply circuit.
    4. If the fault persists, replace the power module.
  • Cause 6: The power module is in overtemperature protection state.

    The handling procedure is the same as that for cause 5.