Alarm Handling

CloudEngine 12800 and 12800E V200R005C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ERPS_1.3.6.1.4.1.2011.5.25.256.4.2 hwErpsFwStateDiscarding

ERPS_1.3.6.1.4.1.2011.5.25.256.4.2 hwErpsFwStateDiscarding

Description

The state of ERPS port was changed to discarding. (RingId=[INTEGER], InterfaceIndex=[INTEGER], InterfaceName=[OCTET])

An ERPS ring port entered the Discarding state.

Attributes

Attribute

Description

Alarm or Event

Event

Trap Severity

Critical

Mnemonic Code

hwErpsFwStateDiscarding

Trap OID

1.3.6.1.4.1.2011.5.25.256.4.2

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the matching trap.

Parameters

Parameter Description
RingId ERPS ring ID
InterfaceIndex Port index
InterfaceName Port name

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.256.1.2.1.1

hwConfigRingId

hwConfigRingId

1.3.6.1.2.1.31.1.1.1.1

ifIndex

ifName

Impact on the System

The topology change may cause traffic loss.

Possible Causes

Cause 1: A new link was added to the ERPS ring.

Cause 2: An ERPS ring port went Up or Down.

Procedure

  1. Check physical devices on the network to see whether a new ERPS-enabled physical link is added.

    • If a new physical link has been added, go to Step 2.

    • If no new physical link has been added, go to Step 3.

  2. Check whether the added physical link is needed.

    • If the added physical link is needed, this trap message is informational only, and no action is required.

    • If the added physical link is not needed, go to Step 4.

  3. Check whether any port added to the ERPS ring goes Up or Down.

    • If a port added to the ERPS ring has gone Up or Down, this trap message is informational only, and no action is required.

    • If no port added to the ERPS ring has gone Up or Down, go to Step 4.

  4. Collect trap, log, and configuration information, and contact technical support personnel.