Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
IPFPM_1.3.6.1.4.1.2011.5.25.316.3.7 hwIpfpmDcpFlowConflict

IPFPM_1.3.6.1.4.1.2011.5.25.316.3.7 hwIpfpmDcpFlowConflict

Description

The flow conflicts with another existing flow.(TestInstanceId=[InstanceId], FlowType=[FlowType], ConflictInstId=[ConflictInstanceId], ConflictFlowType=[ConflictFlowType])

The flow characteristics of a specified target flow in an IP FPM instance conflict with the flow characteristics of a target flow that already exists in another IP FPM instance on the same DCP.

Attributes

Attribute

Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

hwIpfpmDcpFlowConflict

Trap OID

1.3.6.1.4.1.2011.5.25.316.3.7

Alarm ID

0x09d61000

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance. 

Match trap

This is an event trap and does not involve the match trap.

Parameters

Parameter Description

TestInstanceId

IP FPM instance ID

FlowType

Target flow type

ConflictInstId

IP FPM instance ID in conflict

ConflictFlowType

Target flow type in conflict

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.316.2.1.8.1.1

hwIpfpmDcpInstId

hwIpfpmDcpInstId;

1.3.6.1.4.1.2011.5.25.316.2.1.10.1.1

hwIpfpmDcpFlowType

hwIpfpmDcpInstId

hwIpfpmDcpFlowType

1.3.6.1.4.1.2011.5.25.316.2.1.8.1.1

hwIpfpmDcpInstId

hwIpfpmDcpInstId;

1.3.6.1.4.1.2011.5.25.316.2.1.10.1.1

hwIpfpmDcpFlowType

hwIpfpmDcpInstId

hwIpfpmDcpFlowType

Impact on the System

The performance statistics may be incorrect.

Possible Causes

The flow characteristics of a specified target flow in an IP FPM instance overlap with the flow characteristics of a target flow that already exists in another IP FPM instance on the same DCP, causing a flow conflict alarm.

Procedure

  1. Check whether the flow characteristics of a newly configured target flow in an IP FPM instance overlap with the flow characteristics of a target flow that already exists in another IP FPM instance on the same DCP.

    • If so, go to Step 2.
    • If not, go to Step 3.

  2. Check the cause of the flow characteristics overlap and resolve the problem. Then check whether the alarm persists.

    • If so, go to Step 3.
    • If not, go to Step 4.

  3. Collect alarm information and configuration information, and then contact technical support personnel.
  4. End.