Alarm Handling

CloudEngine 12800 and 12800E V200R005C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
EFM_1.3.6.1.4.1.2011.5.25.136.1.6.5 nonthreshold

EFM_1.3.6.1.4.1.2011.5.25.136.1.6.5 nonthreshold

Description

Nonthreshold Event occured. (IfIndex=[INTEGER], EventLogIndex=[GAUGE], EventLogTimestamp=[TIMETICK], EventLogOUI=[OPAQUE], EventLogType=[GAUGE], EventLogLocation=[INTEGER], IfName=[OCTET])

None-threshold-crossing events occur on the link, including LinkLost and LinkFault.

Attributes

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Error

Mnemonic Code

nonthreshold

Trap OID

1.3.6.1.4.1.2011.5.25.136.1.6.5

Alarm ID

0x00f10002

Alarm Type

communicationsAlarm

Raise or Clear

Raise

Match trap

EFM_1.3.6.1.4.1.2011.5.25.136.1.6.17 hwDot3ahEfmNonThresholdRecovery

Parameters

Parameter

Description

IfIndex Indicates the interface index.
EventLogIndex Indicates the index of the printed log.
EventLogTimestamp Indicates the time stamp that records when the event occurs.
EventLogOUI Indicates the OUI of an event.
EventLogType Indicates the type of an event.
EventLogLocation Indicates where the event occurs, on the local end or the remote end.
IfName Indicates the interface name.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.136.1.2.2.7.1.2

hwDot3ahEfmEventLogTimestamp

ifIndex

hwDot3ahEfmEventLogIndex

1.3.6.1.4.1.2011.5.25.136.1.2.2.7.1.3

hwDot3ahEfmEventLogOui

ifIndex

hwDot3ahEfmEventLogIndex

1.3.6.1.4.1.2011.5.25.136.1.2.2.7.1.4

hwDot3ahEfmEventLogType

ifIndex

hwDot3ahEfmEventLogIndex

1.3.6.1.4.1.2011.5.25.136.1.2.2.7.1.5

hwDot3ahEfmEventLogLocation

ifIndex

hwDot3ahEfmEventLogIndex

Impact on the System

Services will be interrupted.

Possible Causes

Cause 1:

The remote interface was not enabled with EFM.

Cause 2:

The interface was shut down; or the physical link went Down.

Procedure

  1. Check the value of the EventLogType field in the trap:

    • 254: indicates the timeout. Then, go to Step 2.

    • 256: indicates that the local interface is shut down. Then, go to Step 3.

  2. Run the display this command in the interface view to check whether EFM is enabled on the remote device.

    • If so, go to Step 4.

    • If not, go to Step 5.

  3. Run the display this command in the interface view to check whether the local interface is shut down.

    • If so, go to Step 6.

    • If not, go to Step 4.

  4. Check whether the physical link is faulty.

    • If so, go to Step 7.

    • If not, go to Step 8.

  5. Run the efm enable command in the interface view of the remote device to enable EFM. Then, check whether the alarm is cleared.

    • If so, go to Step 9.

    • If not, go to Step 8.

  6. Run the undo shutdown command in the interface view to check whether the alarm is cleared.

    • If so, go to Step 9.

    • If not, go to Step 7.

  7. Replace the physical link and then check whether the alarm is cleared.

    • If so, go to Step 9.

    • If not, go to Step 8.

  8. Collect trap messages, log messages, and configurations, and then contact the technical support personnel.
  9. End.