Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
FEI_1.3.6.1.4.1.2011.5.25.32.4.1.11.59 hwXQoSStormSuppressSlotAlarm

FEI_1.3.6.1.4.1.2011.5.25.32.4.1.11.59 hwXQoSStormSuppressSlotAlarm

Description

Packet loss occurred in the slot because of storm suppression.(Slot=[hwXQoSStormSuppressSlotAlarmSlot])

Packets were discarded in the slot due to traffic suppression.

Attributes

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwXQoSStormSuppressSlotAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.32.4.1.11.59

Alarm ID

0x095e2064

Alarm Type

qualityOfServiceAlarm

Raise or Clear

Raise

Match trap

FEI_1.3.6.1.4.1.2011.5.25.32.4.1.11.60 hwXQoSStormSuppressSlotAlarmResume

Parameters

Parameter Description

hwXQoSStormSuppressSlotAlarmSlot

Slot ID.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.32.4.1.40.2.1.1

hwXQoSStormSuppressSlotAlarmSlot

hwXQoSStormSuppressSlotAlarmSlot

Impact on the System

Packets were lost in the slot.

Possible Causes

The rate of packets received in the slot exceeded the traffic suppression threshold.

Procedure

  1. Check whether a loop or attack occurs on the network.
  2. Set a proper traffic suppression threshold.
  3. Collect the alarm, log, and configuration information, and contact technical support personnel.