Alarm Handling

CloudEngine 12800 and 12800E V200R005C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
EOAM-1AG_1.3.6.1.4.1.2011.5.25.136.1.6.46 hwDot1agCfmRDI

EOAM-1AG_1.3.6.1.4.1.2011.5.25.136.1.6.46 hwDot1agCfmRDI

Description

MEP received a CCM with RDI flag set. (MdIndex=[GAUGE],MaIndex=[GAUGE],MdName=[STRING],MaName=[STRING],MepId=[INTEGER],RmepId=[INTEGER])

The RMEP sent a CCM carrying the RDI flag with the value of 1 to the MEP.

Attributes

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Error

Mnemonic Code

hwDot1agCfmRDI

Trap OID

1.3.6.1.4.1.2011.5.25.136.1.6.46

Alarm ID

0x09ac000e

Alarm Type

communicationsAlarm

Raise or Clear

Raise

Match trap

EOAM-1AG_1.3.6.1.4.1.2011.5.25.136.1.6.47 hwDot1agCfmRDICleared

Parameters

Parameter Description
MdIndex Index of an MD table
MaIndex Index of an MA table
MdName Name of an MD
MaName Name of an MA
MepId ID of a MEP
RmepId ID of an RMEP

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.136.1.1.3.2.1.3

hwDot1agCfmMdName

hwDot1agCfmMdIndex;

1.3.6.1.4.1.2011.5.25.136.1.1.4.2.1.2

hwDot1agCfmMaName

hwDot1agCfmMdIndex

hwDot1agCfmMaIndex

1.3.6.1.4.1.2011.5.25.136.1.1.5.1.1.1

hwDot1agCfmMepIdentifier

hwDot1agCfmMdIndex

hwDot1agCfmMaIndex

hwDot1agCfmMepIdentifier

1.3.6.1.4.1.2011.5.25.136.1.1.6.1.1.1

hwDot1agCfmRMepIdentifier

hwDot1agCfmMdIndex

hwDot1agCfmMaIndex

hwDot1agCfmRMepIdentifier

Impact on the System

System performance will not be affected.

Possible Causes

Cause 1: If an RMEP received a non-RDI trap, the RMEP set the RDI flag to 1 in a CCM and sent the CCM to the MEP.

Cause 2: If CFM association was enabled and an associated interface or protocol notified the RMEP of a detected fault, the RMEP set the RDI flag to 1 in a CCM and sent the CCM to the MEP.

Procedure

  1. Run the display cfm remote-mep [ md md-name ma ma-name mep-id mep-id ] command on the RMEP to view the value of the Alarm Status field.

    • If the value of the Alarm Status field is none, go to Step 3.

    • If the value of the Alarm Status field is not none, go to Step 2.

  2. Perform the following steps on the RMEP:

  3. Perform the following steps on the RMEP:
    1. Run the oam-mgr command to enter the MGR view.
    2. Run the display this command. Check whether CFM is associated with an interface or a protocol. If there is no association configuration, go to Step 4.
    3. If CFM is associated with an interface or a protocol, check whether the associated interface or protocol fails. If the associated interface or protocol works properly, go to Step 4. If the associated interface or protocol fails, rectify the fault. Check whether the trap is cleared. If the trap persists, go to Step 4.
  4. Collect the alarm, log, and configuration information, and then contact technical support personnel.