Alarm Handling

CloudEngine 12800 and 12800E V200R005C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
MACSEC_1.3.6.1.4.1.2011.5.25.347.2.3 hwMacsecRcvRspTimeout

MACSEC_1.3.6.1.4.1.2011.5.25.347.2.3 hwMacsecRcvRspTimeout

Description

The MKA protocol status of the local interface becomes Down because the response message cannot be received during the timeout period.(IfIndex=[IfIndex], Role=[Role], Local Port=[LocalPort])

If the MKA protocol is normal and heartbeat packets are not received, an alarm is generated.

Attributes

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwMacsecRcvRspTimeout

Trap OID

1.3.6.1.4.1.2011.5.25.347.2.3

Alarm ID

0x00F10254

Alarm Type

qualityOfServiceAlarm

Raise or Clear

Raise

Match trap

MACSEC_1.3.6.1.4.1.2011.5.25.347.2.4 hwMacsecRcvRspTimeoutResume

Parameters

Parameter Description

IfIndex

Interface index

Role

Device role

LocalPort Local interface

VB Parameters

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.347.1.2.1.1

hwMacsecRcvRspTimeoutIfIndex

hwMacsecRcvRspTimeoutIfIndex

hwMacsecRcvRspTimeoutRole

hwMacsecRcvRspTimeoutLocalPort

1.3.6.1.4.1.2011.5.25.347.1.2.1.2

hwMacsecRcvRspTimeoutRole

hwMacsecRcvRspTimeoutIfIndex

hwMacsecRcvRspTimeoutRole

hwMacsecRcvRspTimeoutLocalPort

1.3.6.1.4.1.2011.5.25.347.1.2.1.3 hwMacsecRcvRspTimeoutLocalPort

hwMacsecRcvRspTimeoutIfIndex

hwMacsecRcvRspTimeoutRole

hwMacsecRcvRspTimeoutLocalPort

Impact on the System

Heartbeat packets are not received.

Possible Causes

Cause 1. The interface goes Down and cannot receive heartbeat packets.

Cause 2: The peer end does not respond.

Procedure

  • Cause 1. The interface goes Down and cannot receive heartbeat packets.
    1. Restore the interface link status and check whether the alarm is cleared.

      • If the alarm is cleared, no further action is required.
      • If the alarm persists, go to step 2.

    2. Collect the alarm, log, and configuration information, and contact Huawei technical support personnel.
  • Cause 2: The peer end does not respond.
    1. Run the display interface command in any view to check the interface status on both devices.

      • If the interfaces on both ends are Up, the device re-negotiates with the peer device, and no action is required.
      • If one or both interfaces are Down, run the undo shutdown command in the interface view to configure both interfaces to go Up. If the alarm persists, go to Step 2.