Alarm Handling

CloudEngine 12800 and 12800E V200R005C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
IFNET_1.3.6.1.4.1.2011.5.25.41.3.49_hwPhysicalAdminIfDown

IFNET_1.3.6.1.4.1.2011.5.25.41.3.49_hwPhysicalAdminIfDown

Description

The physical manage interface physical status changes to down.(ifName=[ifName], OperStatus=[ifOperStatus])

The physical status of a management interface went Down.

Attributes

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwPhysicalAdminIfDown

Trap OID

1.3.6.1.4.1.2011.5.25.41.3.49

Alarm ID

0x08522017

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

IFNET_1.3.6.1.4.1.2011.5.25.41.3.50_hwPhysicalAdminIfUp

Parameters

Parameter

Description

ifName

Name of the physical management interface

ifOperStatus

Status of the physical management interface

VB Parameters

VB OID

VB Name

VB Index

1.3.6.1.2.1.2.2.1.1

ifIndex

ifIndex

1.3.6.1.2.1.31.1.1.1.1

ifName

ifIndex

1.3.6.1.2.1.2.2.1.8

ifOperStatus

ifIndex

Impact on the System

The physical management interface cannot forward packets normally.

Possible Causes

The physical link status of the management interface went Down.

Procedure

  1. Check whether the physical link of the interface is properly connected, including whether hardware such as the network cable and optical module is in loose connection or disconnected.

    • If the physical link is not connected properly, rectify the physical link connection and then check whether the alarm is cleared. If the alarm persists, go to Step 2.
    • If the physical link is properly connected, go to Step 2.

  2. Collect alarm information and configuration information, and then contact technical support personnel.