Alarm Handling

CloudEngine 12800 and 12800E V200R005C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ETRUNK_1.3.6.1.4.1.2011.5.25.178.8.2.6 hwMLagHeartLostResume

ETRUNK_1.3.6.1.4.1.2011.5.25.178.8.2.6 hwMLagHeartLostResume

Description

DFS dual-active detection message forwarding is resumed.

DAD packets can be received and sent.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwMLagHeartLostResume

Trap OID

1.3.6.1.4.1.2011.5.25.178.8.2.6

Alarm ID

0x0ae52002

Alarm Type

communicationsAlarm

Raise or Clear

Clear

Match trap

ETRUNK_1.3.6.1.4.1.2011.5.25.178.8.2.5 hwMLagHeartLost

Parameters

None.

VB Parameters

None.

Impact on the System

DAD works properly.

Possible Causes

The source address of the local or remote device or the link status is corrected.

Procedure

  • This message is informational only and no action is required.