Alarm Handling

CloudEngine 12800 and 12800E V200R005C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
SMLKTRAP_1.3.6.1.4.1.2011.5.25.42.5.2.1 hwSmartLinkLinkSwitch

SMLKTRAP_1.3.6.1.4.1.2011.5.25.42.5.2.1 hwSmartLinkLinkSwitch

Description

Smart link group [SmlkGrpID] status turned to [SmlkGrpStatus].

The status of the Smart Link group changed.

Attribute

Attribute Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

hwSmartLinkLinkSwitch

Trap OID

1.3.6.1.4.1.2011.5.25.42.5.2.1

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the matching trap.

Parameters

Parameter Description
SmlkGrpID Indicates the ID of a Smart Link group.
SmlkGrpStatus Indicates the status of a Smart Link group.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.42.5.1.8.1.4

hwSmartLinkGcGroupStatus

hwSmartLinkGcGroupStatus

Impact on the System

  • If the status changed because a Smart Link group is enabled, the system will not be affected.
  • If the status changed because a Smart Link group is disabled, the system will not be affected.
  • If the status changed because a link switchover is performed in a Smart Link group, traffic forwarding may be affected.

Possible Causes

Cause 1: The smart link group is enabled.

Cause 2: The smart link group is disabled.

Cause 3: The link of smart link group is switched.

Procedure

  • Cause 1: The smart link group is enabled.

    The alarm is informational only, and no action is required.

  • Cause 2: The smart link group is disabled.

    The alarm is informational only, and no action is required.

  • Cause 3: The link of smart link group is switched.

    • If a link switchover is performed manually, the alarm is informational only, and no action is required.
    • If a link switchover is performed automatically, the primary link fails and perform the following steps:
      1. Run the display interface brief command to check the physical status of the master interface on the primary link.

      2. Check whether the cable of the primary link is correctly connected.
        • If the master interface is Up, and the cable is correctly connected, go to Step 3.

        • If the master interface goes Down, and the undo shutdown command does not set the interface to Up, go to Step 3.

      3. Collect trap, log, and configuration information, and contact technical support personnel.