Alarm Handling

CloudEngine 12800 and 12800E V200R005C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
QOS_1.3.6.1.4.1.2011.5.25.32.4.1.11.26 hwXQOSIfLrDiscardAlarmResume

QOS_1.3.6.1.4.1.2011.5.25.32.4.1.11.26 hwXQOSIfLrDiscardAlarmResume

Description

The outgoing traffic on the interface recovered from congestion.(Interface=[hwXQoSIfLrCfgIfName], CIR=[hwXQoSIfLrCir] kbps, alarm threshold=[hwXQoSTrapThreshold] of the percentage)

The rate of outgoing traffic on an interface is smaller than the alarm threshold for the CIR.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Error

Mnemonic Code

hwXQoSIfLrDiscardAlarmResume

Trap OID

1.3.6.1.4.1.2011.5.25.32.4.1.11.26

Alarm ID

0x09622005 (0d157425669)

Alarm Type

qualityOfServiceAlarm

Raise or Clear

Clear

Match trap

QOS_1.3.6.1.4.1.2011.5.25.32.4.1.11.25 hwXQOSIfLrDiscardAlarm

Parameters

Parameter Description

hwXQoSIfLrCfgIfName

Name of the interface configured with traffic shaping.

hwXQoSIfLrCir

CIR.

hwXQoSTrapThreshold

Alarm threshold.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.32.4.1.20.4.1.1

hwXQoSIfLrDiscardAlarmIfIndex

hwXQoSIfLrDiscardAlarmIfIndex

1.3.6.1.4.1.2011.5.25.32.4.1.20.4.1.2

hwXQoSIfLrDiscardAlarmIfName

hwXQoSIfLrDiscardAlarmIfIndex

1.3.6.1.4.1.2011.5.25.32.4.1.20.4.1.3

hwXQoSIfLrDiscardAlarmCir

hwXQoSIfLrDiscardAlarmIfIndex

1.3.6.1.4.1.2011.5.25.32.4.1.20.4.1.4

hwXQoSIfLrDiscardAlarmTrapThreshold

hwXQoSIfLrDiscardAlarmIfIndex

Impact on the System

Services will not be affected.

Possible Causes

The rate of outgoing traffic on an interface is smaller than the alarm threshold for the CIR.

Procedure

  1. This message is informational only and no action is required.