Alarm Handling

CloudEngine 12800 and 12800E V200R005C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
DEVM_1.3.6.1.4.1.2011.5.25.219.2.1.3 hwChassisFail

DEVM_1.3.6.1.4.1.2011.5.25.219.2.1.3 hwChassisFail

Description

The chassis partially failed. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=[EntityTrapFaultID], Reason=[Reason])

The chassis partially failed.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwChassisFail

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.1.3

Alarm ID

0x081300b4

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.1.4 hwChassisFailResume

Parameters

Name Meaning

EntityPhysicalIndex

Indicates the index of an entity.

EntPhysicalName

Indicates the name of an entity.

EntityTrapFaultID

Indicates the error code.
  • 131586

  • 131336

  • 131337

  • 131338

  • 131339

  • 131340

  • 131341

Reason

Indicates a possible cause.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

N/A

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

N/A

Impact on the System

The system may fail to function properly.

Possible Causes

Cause 1 (EntityTrapFaultID=[131586]): Different SFUs were installed in the same chassis.

Cause 2 (EntityTrapFaultID=[131336]): The system power or the power of the backup power supply is insufficient.

Cause 3 (EntityTrapFaultID=[131337]): No SFU is present in the chassis.

Cause 4 (EntityTrapFaultID=[131338]): No LPU is present in the chassis.

Cause 5 (EntityTrapFaultID=[131339]): No CMU is present in the chassis.

Cause 6 (EntityTrapFaultID=[131340]): Communication between the CMUs failed.

Cause 7 (EntityTrapFaultID=[131341]): Failed to obtain slot information of the power supply.

Procedure

  • Cause 1: Different SFUs were installed in the same chassis.
    1. Install SFUs correctly.
  • Cause 2: The system power or the power of the backup power supply is insufficient.
    1. Add power modules.
  • Cause 3: No SFU is present in the chassis.
    1. Insert SFU boards.
  • Cause 4: No LPU is present in the chassis.
    1. Insert LPU boards.
  • Cause 5: No CMU is present in the chassis.
    1. Insert CMU boards.
  • Cause 6: Communication between the CMUs failed.
    1. Replace the faulty CMU board.
  • Cause 7: Failed to obtain slot information of the power supply.
    1. Insert the power module into another slot. If the fault persists, replace the power module.