Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
BFD_1.3.6.1.4.1.2011.5.25.38.3.3 hwBfdSessReachLimit

BFD_1.3.6.1.4.1.2011.5.25.38.3.3 hwBfdSessReachLimit

Description

The session number in all the IO boards has reached the limit, the new session can not be created. (TotalSessionLimit=[TotalSessionLimit])

The number of global BFD sessions exceeded the upper limit.

Attributes

Attribute

Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

hwBfdSessReachLimit

Trap OID

1.3.6.1.4.1.2011.5.25.38.3.3

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the matching trap.

Parameters

Parameter Description

SessLimitNumber

Upper limit of global BFD sessions

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.38.1.3

hwBfdSessLimitNumber

None

Impact on the System

No more BFD sessions can be set up.

Possible Causes

New BFD sessions were set up when the maximum number of BFD sessions allowed for each interface had been set up.

Procedure

  1. Stop configuring BFD sessions.
  2. Delete unwanted BFD sessions.
  3. Collect log messages and contact technical support personnel.
  4. End.