No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

CloudEngine 12800 and 12800E V200R005C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.23 hwStackMemberAdd

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.23 hwStackMemberAdd

Description

The stack member device joined in. (hwStackIdIndex=[hwStackIdIndex], hwStackId=[hwStackId], hwStackMacAddress=[hwStackMacAddress])

The stack member device joined in.

Attribute

Attribute

Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

hwStackMemberAdd

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.23

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the matching trap.

Parameters

Parameter Meaning
hwStackIdIndex ID index of the stack member.

hwStackId

ID of the stack member.

hwStackMacAddress MAC address of the device.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.25.1.6

hwStackId

hwStackIdIndex

Impact on the System

A new member device joins the stack system.

Possible Causes

A new member device joins the stack system.

Procedure

  1. Check whether the member device is added manually.

    • If so, no action is required.

    • If no, go to step 2.

  2. Run the display stack configuration command to check whether the stack configuration complies with the requirement.

    • If so, go to step 3.
    • If no, modify the stack configuration and remove excess stack member devices.

  3. Collect trap messages, log messages, and configurations, and then contact technical support personnel.
Translation
Download
Updated: 2019-04-20

Document ID: EDOC1100039527

Views: 89738

Downloads: 21

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next