Alarm Handling

CloudEngine 12800 and 12800E V200R005C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
NQA_1.3.6.1.4.1.2011.5.25.111.6.2 nqaResultsTestFailed

NQA_1.3.6.1.4.1.2011.5.25.111.6.2 nqaResultsTestFailed

Description

NQA entry test failed. (OwnerIndex=[OwnerIndex], TestName=[TestName], TargetAddressType=[TargetAddressType], TargetAddress=[TargetAddress], OperStatus=[OperStatus], Index=[Index], HopIndex=[HopIndex], AddressType=[AddressType], Address=[Address], CompletionTimeMin=[CompletionTimeMin], CompletionTimeMax=[CompletionTimeMax], SumCompletionTime=[SumCompletionTime], ProbeResponses=[ProbeResponses], SentProbes=[SentProbes], SumCompletionTime2Low=[SumCompletionTime2Low], SumCompletionTime2High=[SumCompletionTime2High], LastGoodProbe=[LastGoodProbe], LastGoodPath=[LastGoodPath])

Indicates that the number of continuous testing failures in a test instance reached the set threshold. The value of the default threshold was 1, that is, a trap was generated right after each test failure. The test-failtimes command can modify the threshold.

Attributes

Attribute

Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

nqaResultsTestFailed

Trap OID

1.3.6.1.4.1.2011.5.25.111.6.2

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the matching trap.

Parameters

Parameter Description

OwnerIndex

Administrator of an NQA test instance

TestName

Name of an NQA test instance

TargetAddressType

Destination address type of an NQA test instance

TargetAddress

Destination address of an NQA test instance

OperStatus

Status of an NQA test instance

Index Index of the result table
HopIndex Hop index
AddressType Address type of an NQA test instance
Address Address of an NQA test instance
CompletionTimeMin Minimum RTT value of an NQA test instance
CompletionTimeMax Maximum RTT value of an NQA test instance
SumCompletionTime RTT sum of an NQA test instance.
ProbeResponses Statistics on received packets
SentProbes Statistics on sent packets
SumCompletionTime2Low Sum of RTT squared right 32 bits
SumCompletionTime2High Sum of RTT squared left 32 bits
LastGoodProbe Time when the latest returned packet is received
LastGoodPath Time when the last complete path is obtained

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.111.2.2.1.1

nqaAdminParaTargetAddressType

nqaAdminCtrlOwnerIndex

nqaAdminCtrlTestName

1.3.6.1.4.1.2011.5.25.111.2.2.1.2

nqaAdminParaTargetAddress

nqaAdminCtrlOwnerIndex

nqaAdminCtrlTestName

1.3.6.1.4.1.2011.5.25.111.2.3.1.9

nqaScheduleOperStatus

nqaAdminCtrlOwnerIndex

nqaAdminCtrlTestName

1.3.6.1.4.1.2011.5.25.111.4.1.1.19

nqaResultsAddressType

nqaAdminCtrlOwnerIndex

nqaAdminCtrlTestName

nqaResultsIndex

nqaResultsHopIndex

1.3.6.1.4.1.2011.5.25.111.4.1.1.20

nqaResultsAddress

nqaAdminCtrlOwnerIndex

nqaAdminCtrlTestName

nqaResultsIndex

nqaResultsHopIndex

1.3.6.1.4.1.2011.5.25.111.4.1.1.11

nqaResultsCompletionTimeMin

nqaAdminCtrlOwnerIndex

nqaAdminCtrlTestName

nqaResultsIndex

nqaResultsHopIndex

1.3.6.1.4.1.2011.5.25.111.4.1.1.12

nqaResultsCompletionTimeMax

nqaAdminCtrlOwnerIndex

nqaAdminCtrlTestName

nqaResultsIndex

nqaResultsHopIndex

1.3.6.1.4.1.2011.5.25.111.4.1.1.8

nqaResultsSumCompletionTime

nqaAdminCtrlOwnerIndex

nqaAdminCtrlTestName

nqaResultsIndex

nqaResultsHopIndex

1.3.6.1.4.1.2011.5.25.111.4.1.1.21

nqaResultsProbeResponses

nqaAdminCtrlOwnerIndex

nqaAdminCtrlTestName

nqaResultsIndex

nqaResultsHopIndex

1.3.6.1.4.1.2011.5.25.111.4.1.1.22

nqaResultsSentProbes

nqaAdminCtrlOwnerIndex

nqaAdminCtrlTestName

nqaResultsIndex

nqaResultsHopIndex

1.3.6.1.4.1.2011.5.25.111.4.1.1.9

nqaResultsSumCompletionTime2Low

nqaAdminCtrlOwnerIndex

nqaAdminCtrlTestName

nqaResultsIndex

nqaResultsHopIndex

1.3.6.1.4.1.2011.5.25.111.4.1.1.10

nqaResultsSumCompletionTime2High

nqaAdminCtrlOwnerIndex

nqaAdminCtrlTestName

nqaResultsIndex

nqaResultsHopIndex

1.3.6.1.4.1.2011.5.25.111.4.1.1.23

nqaResultsLastGoodProbe

nqaAdminCtrlOwnerIndex

nqaAdminCtrlTestName

nqaResultsIndex

nqaResultsHopIndex

1.3.6.1.4.1.2011.5.25.111.4.1.1.24

nqaResultsLastGoodPath

nqaAdminCtrlOwnerIndex

nqaAdminCtrlTestName

nqaResultsIndex

nqaResultsHopIndex

Impact on the System

None.

Possible Causes

1.

The destination address was inexistent and unreachable.

2.

The destination address exists, but the route was unreachable.

3.

Because of the network latency, the Rtt of the packet was longer than the set timeout period.

Procedure

  1. Run the display this command in the NQA test view to check whether the destination address is correctly configured

    • If so, go to Step 2.
    • If not, run the destination-address command in the NQA test view to modify the destination address. Perform the test again to check whether the alarm is cleared.

      • If so, go to Step 5.
      • If not, go to Step 2.

  2. Run the ping command in the NQA test view to check whether the route is reachable.

    • If the route is reachable, go to Step 3.
    • If the destination address is correctly configured, but the route is not reachable, run the display ip routing-table command to check and routing table and rectify the routing fault. Perform the test again to check whether the alarm is cleared.
      • If so, go to Step 5.
      • If not, go to Step 3.

  3. Run the timeout command in the NQA test view to modify the timeout period according to the status of the current network. It is recommended that you modify the timeout period to the default value, that is, three seconds. The value of the timeout period ranges from 1 second to 60 seconds. You can run the display this command in the NQA test view to see the current timeout period.

    Perform the test again to check whether the alarm is cleared.

    • If so, go to Step 5.
    • If not, go to Step 4.

  4. Contact technical support personnel.
  5. End.