Alarm Handling

CloudEngine 12800 and 12800E V200R005C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
DRIVER_1.3.6.1.4.1.2011.5.25.219.2.2.8 hwBoardBecomeMaster

DRIVER_1.3.6.1.4.1.2011.5.25.219.2.2.8 hwBoardBecomeMaster

Description

Board changed to the master state.(EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityType=[EntityType], EntityTrapFaultID=[EntityTrapFaultID],Reason=Master/Slave Board Switchover.)

The standby board became the active board.

Attributes

Attribute

Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

hwBoardBecomeMaster

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.2.8

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the matching trap.

Parameters

Name Meaning

EntityPhysicalIndex

Indicates the index of an entity.

EntPhysicalIndex

Indicates the index of an entity.

EntPhysicalName

Indicates the name of an entity.

EntityType

Indicates the entity type.

EntityTrapFaultID

Indicates the error code: 133120.

Reason

Indicates a possible cause.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

N/A

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.2

hwEntityTrapEntType

N/A

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

N/A

Impact on the System

If no active/standby switchover is performed, the active MPU may be faulty.

Possible Causes

The master/slave switchover was performed or the active MPU was faulty.

Procedure

  1. Check whether active/standby switchover was performed.

    • If so, no action is required.

    • If not, go to step 2.

  2. Run the display device [ slot slot-id ] command to check whether the original active MPU has been registered successfully.

    • If so, go to step 4.

    • If not, go to step 3.

  3. Remove and install the original active MPU. After the MPU is started successfully, check whether the MPU is registered successfully.

    • If so, go to step 4.

    • If not, go to step 5.

  4. Check whether the original active MPU is faulty. Check whether the active/standby switchover can be performed.

    • If so, go to step 6.

    • If not, go to step 5.

  5. Collect traps, logs, and configurations, and contact technical support personnel.
  6. End